C1250 Installation Guide
8 LED Blink Codes
LED Blink Codes
Error
Warn
EN
Description
Off
Warning
Operation
Enabled
Normal Operation:
Warnings and operation enabled are displayed.
On
●
~2Hz
0..15 x
Error Code
High Nibble
●
~2Hz
0..15 x
Error Code
Low Nibble
Error
:
The error code is shown by a blink code with “WARN” and “EN”.
The error byte is divided into low and high nibble (= 4 bit).
”WARN” and “EN” are blinking together.
The error can be acknowledged.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
●
~2Hz
●
~2Hz
0..15 x
Error Code
High Nibble
●
~2Hz
0..15 x
Error Code
Low Nibble
Fatal Error
:
The error code is shown by a blink code with “WARN” and “EN”.
The error byte is divided into low and high nibble.
”WARN” and “EN” are blinking together.
Fatal errors can only be acknowledged by a reset or power cycle.
(e.g.: WARN blinks 3x, EN blinks 2x; Error Code = 32h)
●
~4Hz
●
~2Hz
0..15 x
Error Code
High Nibble
●
~2Hz
0..15 x
Error Code
Low Nibble
System Error:
Please reinstall firmware or contact support.
●
~0.5Hz
●
~0.5Hz
On
Signal Supply 24V too low:
The error and warn LEDs blink alternating if the signal 24V (X4.2) is
less than 18VDC.
Off
M
●●●
●
M
●●
Plug&Play Communication Active
This sequence (Warn on, then En on, then both off, complete sequence of the 4
states ca. 1Sec) signalizes the state when the plug and play parameters are
being read from the motor.
M
●
~4Hz
●
M
~4Hz
off
Waiting for Defaulting Parameters
When ID (S1, S2) is set to 0xFF, the drive starts up in a special mode and the
Error and Warn LED blink alternating ~4Hz. When the ID ist set to 0x00, all
parameters will be set to their default value. To leave this state, power down the
drive and change the ID. Also see in the Usermanual_LinMot-Talk under
chapter trouble shooting.
Off
M
●
~2Hz
M
●
~2Hz
Defaulting Parameters Done
When the parameters have set to their default values (initiated via S1/S2 on
power up) the Warn and En LEDs blink together at 2 Hz. To leave this state,
power down the drive. Also see in the Usermanual_LinMot-Talk under chapter
trouble shooting.
The meaning of the error codes can be found in the
Usermanual_MotionCtrl_Software_SG5 and the user manual of the installed
interface software. These documents are provided together with LinMot-Talk
configuration software and can be downloaded from
www.linmot.com
.
NTI AG / LinMot
®
www.LinMot.com
Page 15/26