Press [▼] or [▲].  until you get to the program you wish to activate; the display will flash. 

  Comf or Econ will show in the display. Also the temperature will flash 

  Press [OK] 

 
4.2

) Deactivate “Econ” or “Comf” 

If the time zone temperature is overridden by 

“Econ” or “Comf”, it can be deactivated like this: 

  Press [P] 

  Press 

[▲] 

  Program will flash 

  Press [OK] 

“Econ” or “Comf” is now no longer active and is not displayed 

 

5)  Changing max. and min. limits for monitoring floor temperature 

– in day and night setback 

This function is only active, if HC10B has been selected to operate with combined room and floor sensor (CO) 
Changing the factory-set values of max. 27 

o

C and min. 15 

o

C  

  Press [P] 

  PROGRAM will flash 

 

Press [P]  

  The day(s) on the display will flash 

  Press [P] 

  Time zone will flash 

  Press 

[▼] or [▲] until program Max or Min flashes on the display. 

  Press [

  The temperature will flash 

 

Use [▼] or [▲] to set the temperature. 

  Press [OK] 

  The selected PROGRAM will flash. 

 

Use [▼] or [▲] to select the program which you now wish to change. 
or 

  Exit by pressing [OK] for 2 seconds. 

 

5a)  Changing max. limit - in Quickstart 

The function is active when the floor sensor is connected / installed. Limit temperature is measured by the floor sensor. 
Select maximum limitation temperature. The factory setting is 27 

o

C. Possible setting is 26 to 45 

o

C. 

  Press [

] for 2 seconds. 

  Sensor will flash. 

  Press [

  The temperature will flash. 

 

Use [▼] or [▲] to change the limit temperature. 

  Exit by pressing [OK] 

 

6)  Changing from Quickstart to Night and day setback 

Change from Quickstart program to Night and day setback program 

  Press [P] 

  PROGRAM will flash 

  Press [OK] 

HC10B will now operate night and day setback 
The previously set times and temperatures in Night and day setback are saved. 
 

7)  Changing from Night and day setback to Quickstart 

Change from Night and day setback program to Quickstart program 

  Press [

  FL: - - flashes 

  Press [OK] 

HC10B will now operate with Quickstart.  
The previously set times and temperatures in Night and day setback are not deleted on changing to Quickstart. 
 

8)  Switching between display of actual room temperature and desired temperature 

  Simultaneously press [

]+[OK]. Hold them in for min. 3 seconds. 

  This will switch the display between actual or desired room temperature.  

Switch back in the same way. 

  Simultaneously press [

]+[OK]. Hold them in for min. 3 seconds. 

  The display will switch back again. 

 

9)  Read out actual floor temperature 

Apply only if floor sensor is connected 

  Press [

  Actual temperature is shown in the display for 10 seconds. I.e. FL :22 

 

10)  Turning HC10B on and off 

 

Press [▼] and [▲] simultaneously. 
HC10B will turn off 

  Press any key to turn HC10B on again 