2
Program 1: Settings for Monday to Friday, and settings for Saturday and Sunday.
Time zone
Mon - Fri
Temperature
Sat - Sun
Temperature
Wake
5:00
– 8:30
22
o
C
7:00
– 23:00
22
o
C
Leave
8:30
– 15:00
18
o
C
Home
15:00
– 22:00
22
o
C
Sleep
22:00
– 5:00
18
o
C
7:00
– 23:00
18
o
C
Program 2: Settings for All Weekdays.
Time zone
All days
Temperature
Wake
7:00
– 23:00
22
o
C
Sleep
23:00
– 7:00
18
o
C
Program 3: Settings for Each Day of the Week separately.
Time zone
Mon, Tue…..
Temperature
Wake
5:00
– 8:30
22
o
C
Leave
8:30
– 15:00
18
o
C
Home
15:00
– 22:00
22
o
C
Sleep
22:00
– 5:00
18
o
C
D) Floor and room sensors
Two sensors, a floor sensor and a room sensor provide HC10B with feedback on the current temperature in the room or the floor.
The feedback from the sensors is necessary to maintain the desired temperature in the room.
The sensors can be used separately or together.
Floor sensor (FL)
Room sensor (RO)
Combined use of room and floor sensor (CO).
In (CO) setting, the room sensor controls the room temperature, while the floor temperature*) is simultaneously monitored by
the floor sensor. The HC10B monitor is set to a desired minimum temperature and a desired maximum temperature. The
factory settings are 27 and 15
o
C respectively. (CO) should be selected when heating is installed under a timber floor.
*) Temperature measured by floor sensor.
E) HC10B backup battery
HC10B is equipped with a battery ensuring around 100 hours' backup. If the power has failed and the backup battery is active, the
display will show OFF. If Heat Control has been without power for more than around 100 hours, the backup battery will be empty.
When the power returns again, HC10B will start up with the factory settings Quickstart and 21 degrees.
Any changes made to the programs will be lost.
Programming the HC10B.
1) Important! Start here
before you activate any night and day setback program
Set the day of the week and the clock.
Press [P] and confirm with [OK]
Hours will flash
Use [▼] or [▲] to set the hours.
Press [
]
Minutes will flash
Use [▼] or [▲] to set the minutes.
Press [
]
Day will flash
Use [▼] or [▲] to choose present day. i.e. Mon = Monday, Tue = Tuesday
Confirm by pressing [OK].
2) Setting the functions and altering the programs
2.1) Set HC10B to floor sensor
Press [
] for approx. 4 secs.
(FL), (RO) or (CO) will flash on the display.
Press one of the arrow keys [▼] or [▲] until (FL) shows on the display.
Confirm by pressing [OK].
The underfloor heating will now be controlled by the signal from the floor sensor. The display will show the temperature the floor will
reach.
Note: The temperature shown on the display will typically be lower than the room temperature.
2.2) Setting HC10B to room sensor
The use of room sensor is recommended if there is no floor sensor in the floor.
Press [
] for approx. 4 secs.
(FL), (RO) or (CO) will flash on the display.
Press one of the arrow
keys [▼] or [▲] until (RO) shows on the display.
Confirm by pressing [OK].
The underfloor heating will now be controlled by the signal from the room sensor. The display will show the temperature the air in