SET-UP:
Fill the holding tank with clear water and the detergent of your choice. Mix well. Although this
machine is designed to supply instant hot water, the addition of warm or hot water to the holding
tank would be a plus factor.
1. Plug in cord #1, identified by the 4" long red band on the end of the cord. (This cord runs the
pump and vacuums).
2. Turn on the pump and spray through the cleaning tool for a few seconds to fill the lines with
solution.
3. Plug in cord #2. IF THE GREEN LIGHT ILLUMINATES, THE HEAT EXCHANGER WILL
TURN ON AUTOMATICALLY (SEE NOTE BELOW). Wait 2 minutes for the heat exchanger
to reach operating temperature. You may now begin cleaning. It will take about 10 seconds
for the initial heat to reach the wand.
NOTE: 240 Volt machines do not have a green light.
NOTE: If the green circuit indicator light does not illuminate when cord #2 is plugged in,
then both cords are on the same circuit. Try other outlets until the light comes on. See
bypass switch section (below) if you are unable to get a green light.
BYPASS SWITCH:
NOTE: 240 Volt machines do not have a Bypass Switch.
The bypass switch completely bypasses the circuit locator. Use this feature when you cannot
get the green light to come on and you believe that the two cords are on separate circuits.
CAUTION: If the bypass switch is on and the two cords are plugged into the same circuit,
the breaker will blow.
ELECTRIC CIRCUIT LOCATOR:
NOTE: 240 Volt machines do not have an Electronic Circuit Locator.
This unique, patented “smart system”, operated by a solid state circuit, will inform the operator
when the two cords are plugged into separate lines by illuminating the green indicator light. This
helps prevent tripping circuit breakers.
BALL FLOAT VAC SHUTOFF:
When the recovery tank is full, the float system will shut off the incoming air flow and prevent
water from entering the vacuum motors. The float may not work properly if the float filter is
clogged or if there is heavy foam in the tank.
CAUTION: To avoid vac motor damage, always make sure the float filter is clean and the ball
travels freely before turning on the machine. Use a defoamer whenever foam is present.
SAFETY PRECAUTIONS:
All extension cords must have a rating of at least 12/3 (#12 cord). Extension cords should be
no longer than 50 feet. Replace the plug immediately if the ground prong becomes damaged
or is broken off. Not only is the ground necessary for safety, but the circuit locator system
will not operate correctly without it.
https://harrissupplyind.com - To Order Parts Call 608-268-8080