Introduction  

 

We are pleased that you have chosen our product 

PODIAVAC

 
In order to use the device in a proper and safe manner it is important that you read these operating 
instructions carefully prior using the device for the first time.  
 
PODIAVAC  is  a  compact  foot  care  device  for  the  dry  technology  which  is  based  on  state-of-the-art 
technology. It is used for treatments which can be employed in foot care or pedicure/ manicure.   
 
Our  device  is  equipped  with  an  powerful  high-speed,  ergonomically  shaped  hand-piece.  The  low-
vibration precision micro-motor in the hand-piece facilitates convenient  operation. A safe and secure 
exchange of the grinder is made possible by means of an automatic chuck on the hand-piece.  
 
The  brushless  high-speed  hand-piece  motor  and  an  suction  system  integrated  into  the  hand-piece 
ensure excellent conditions for pain-free and hygienic treatment.  
A dust bag made of micro-fibre material ensures a maximum of safety.  
 
All functions of the device are displayed on the front panel. In this way you can simply check the set 
speed, the rotating speed of the grinder and the suction capacity.  
 
With the help of the optional foot switch you have the possibility of keeping your hands free for your 
work.  

 

Important notes 

 

Attention! 

Please  check  after  unpacking  whether  the  device  is  complete  and  has  not  been 

damaged  during  transport.  If  there  is  any  doubt,  you  should  immediately  contact  our  customer 
service.

 

  

 
Please read the following safety instructions carefully.  

Adequate ventilation of the device is necessary to prevent inside the unit too much heat.  
Imagine, the PODIAVAC should not be placed in the vicinity of heat sources, such as e.g. radiators or 
air vents.  
The ventilation slots on the device must not be blocked and the device must not be covered or built 
in.   
Wait until the device has adjusted to the ambient temperature before using it (e.g. after a cold night 
in a car) to avoid condensation forming on the device. 

 

PODIAVAC is not suitable for use in wet areas (such as the bathroom)

 

(see technical data). 

 

If a liquid or any particles reach into the inner of the device, it should be switched off immediately and 
disconnected from the power supply. Check by an authorized dealer before continuing the use of the 
device. 
 
Keep the device out of the reach of children and unauthorized persons! 
 

Attention  !

    Always  pull  the  mains  plug  before  cleaning  the  device  or  replacing  the  fuse!  Never 

operate the device without a grinder. If you are not working with the hand-piece, always insert a blind 
pin.  Only  use  grinders  with  a  maximum  diameter  of  6  mm.  Take  the  manufacturer’s  specifications 
regarding the maximum speed into account. Only insert dry grinders into the hand-piece.  
Never place the hand-piece in a liquid, otherwise irreparable damage might be caused for which the 
manufacturer accepts no liability!  

Attention !

    Never operate the device without a dust bag.  

Summary of Contents for PDV30

Page 1: ...PODIAVAC PDV30 Operating Instructions ...

Page 2: ... the rotational direction of the tool 6 Switching the hand piece 6 Tool change 7 Separate switching on and off of the suction system 7 Switching off the device 7 General notes 7 General care maintenance and repair 8 Cleaning the device 8 Replacing the dust bag 8 Cleaning the hand piece 8 Disinfection cleaning and storing the tools 9 Maintenance 9 Malfunctions and trouble shooting 10 Changing the f...

Page 3: ...aged during transport If there is any doubt you should immediately contact our customer service Please read the following safety instructions carefully Adequate ventilation of the device is necessary to prevent inside the unit too much heat Imagine the PODIAVAC should not be placed in the vicinity of heat sources such as e g radiators or air vents The ventilation slots on the device must not be bl...

Page 4: ... of the tool ROTATION 8 Counter clockwise clockwise rotation of the tool L R 9 Service LED for maintenance 10 Memory for stored speed values 2x 11 Speed control rotation Increase speed Reduce speed 12 Display for vacuum power 13 ON OFF pushbutton for suction Vacuum 14 Level indicator dust bag 15 Control of suction capacity Increase capacity Reduce capacity 16 Memory for stored vacuum values 2x 3 2...

Page 5: ...evice below the fixing hole for the hand piece Mains supply Connect the supplied power cable with the power inlet on the right side of the device Attention Check the voltage V specified on the label before connecting the device to the supply voltage Plug the power cord into a wall outlet with adequate protection contact The device is now ready for operation Warranty The term of the warranty for Po...

Page 6: ...utton of the speed controller 11 to increase or reduce the speed The speed is controllable in steps of 1000 from 5000 up to 12000 and Steps of 2000 from 12000 up to 30000 min 1 The selected speed is displayed by the corresponding display 6 on the front panel Setting of suction Press the or pushbutton of the vacuum power control 15 to increase or reduce suction The suction capacity vacuum set is di...

Page 7: ...hed on again at this point Separate switching on and off of the suction system Press the ON OFF pushbutton VACUUM 13 for the suction system The suction system is switched off The grinder continues to operate Press the ON OFF pushbutton VACUUM 13 for the suction system once again in order to switch the suction system once again Switching off the device Press the I O pushbutton 5 The device is now i...

Page 8: ...r damaging it The guide pins of the connection of the hand piece have to be inserted into the guiding holes of the suction chamber Make sure that the contact pin is not damaged by any jamming which may occur Cleaning the hand piece NEVER clean the hand piece using boiling water chemicals wire brushes or ultra sound NEVER immerse the hand piece in a disinfectant or ultrasonic bath NEVER place or im...

Page 9: ...nd repair may only be carried out by authorised skilled staff of the manufacturer Unauthorised persons are not permitted to open the device under any circumstances In case of changes and repairs by staff not authorised to that end any warranty or liability on the part of the manufacturer ceases to apply During the regular maintenance of the device an examination according to DIN VDE 0702 0751 has ...

Page 10: ...Grinder is blocked Check connection between the plug of the hand piece and the device Ensure unobstructed operation of the grinder Start Stop pushbutton 7 Reduced suction capacity Dust bag is full Exchange the dust bag In case of further problems or malfunctions please contact your dealer or the manufacturer Changing the fuse Caution Fuses may only be exchanged after the power plug has been unplug...

Page 11: ...vice incl the hand piece to our customer service department for maintenance If required you can request a replacement device In order to be able to continue working switch off the device with the Start Stop pushbutton 7 and switch on once again As long as no device maintenance happened this procedure must be repeated at every switching on the device Please remember If the maintenance intervals are...

Page 12: ...NSK Wellness Technology GmbH Address Portitzer Strasse 69 d D 04425 Taucha Germany We certifies that the product Purpose of equipment Foot Care Equipment Type of equipment PODIAVAC Article no 9160 1 in accordance with the following standards EN 61000 6 1 2001 EN 61000 6 3 2001 Taucha 2012 01 01 NSK Wellness Technology GmbH Managing Director Dieter Bauch Operating instructions GA9160_4 E_V2_0 2012 ...