8
›
When the selected temperature has been reached, the heater demagnetises the workpiece, switches off, and generates
an acoustic signal for 10 seconds or until START/STOP is pressed�
›
Press START/STOP to stop the heater�
›
Always wear protective gloves and other appropriate protective equipment when removing the hot workpiece� NB: Risk of
burning� The workpiece may also be removed using suitable handling equipment�
›
If the workpiece remains on the heater, the heater will start again when the temperature of the workpiece drops 10°C (18°F)�
Press START/STOP to stop the heater and demagnetise the workpiece�
›
The device is now ready to heat another workpiece with the same settings�
4.4 Time Mode
›
If the main display shows °C or °F, press MODE to select TIME MODE� The main display shows “t” in TIME MODE�
›
Press UP or DOWN to adjust the time in steps of 0�1 minute�
›
Press POWER to select the power level� Use the guidelines in section 4�8 to determine the correct power setting�
›
Press START/STOP to start the heater� The main display shows the time that remains�
›
When the time has elapsed, the heater demagnetises the workpiece, switches off, and generates an acoustic signal for
10 seconds�
›
Press START/STOP to turn the induction heater off�
›
Always wear protective gloves and other appropriate protective equipment when removing the hot workpiece� NB: Risk of
burning� The workpiece may also be removed using suitable handling equipment�
›
Remove the workpiece using proper handling equipment�
›
The device is now ready to heat the next workpiece with the same settings�