Caution: Please disconnect power before removing cover for service as high voltage is otherwise present. 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

 
 
 

 
 
 
 
 

TROUBLESHOOTING GUIDE

 

 

SYMPTOM 

CHECK LIST 

NO OUTPUT, LED INDICATORS SHOW 

1. CHECK CHANNEL FUSES. (REFER TO 

STATUS OKAY 

DIAGRAM BELOW) 

NO POWER 

1. CHECK LINE FUSE (REFER TO DIAGRAM 

BELOW) 

2. IF FUSE BLOWS AFTER REPLACEMENT CHECK 

TRANSFORMER. 

1.CHECK CHANNELS FUSES 

2. CHECK FIXTURE LAMPS 

3. CHECK BLACKOUT FREATURE ON CONSOLE 

4. CHECK DIPSWITCH ASSIGNMENT 

5. CHECK MAXIMUM DIMMER ASSIGNMENT ON 

CONTROL CONSOLE 

6. CHECK SOFTPATCH ON CONTROL CONSOLE 

1. CHECK DIP SWITCH ASSIGNMENT. 

2. CHECK SIGNAL CABLE 

3. CHECK MAXIMUM DIMMER ASSIGNMENT AT 

CONSOLE 

4. CHECK OUTPUT MODE OF CONTROL CONSOLE. 

1. TRANSMISSION LENGTH MAY BE A PROBLEM. GET 

CONSOLE CLOSER WlTH A SHORTER CABLE TO VERIFY. 

REMEDY MAY BE THE USE OF 18 GAUGE CABLE OR AN 

EXTERNAL POWER SUPPLY AT THE CONSOLE. (CALL 

DEALER OR NSI TECHNICAL SERVICES FOR DETAILS). 

2. CHECK PRE-HEAT SETTING OF CONSOLE. 

LIGHTS ALWAYS OFF 

LIGHTS ON ALWAYS 

LED INDICATORS ON DIMMER PACK FLICKER 

OR GLOW DIMLY. 

LINE FUSE 

~ STANDARD 3/10 AMP SLO BLO 

CHANNEL FUSE LOCATION 

REPLACE WITH VALUES AS LISTED BELOW 
ND4600 8 AMP FAST BLO 
ND5000 15 AMP FAST BLO NRD 800015 AMP FAST BLO 

IF PROBLEMS PERSIST CONT ACT YOUR NEAREST NSI AUTHORIZED DEALER OR NSI TECHNICAL SERVICES 

AT 800-864-2502 BETWEEN THE HOURS OF 8:00 AM TO 5:00 PM PST MONDAY THRU FRIDAY. 

Summary of Contents for NRD 8000

Page 1: ...NRD 8000 ADDRESSABLE DIMMER PACK OPERATION MANUAL...

Page 2: ...simplified through the abi1ity to daisy chain additional dimmer packs to an existing system This application of microplex technology makes system set up and operation easy and convenient In addition N...

Page 3: ...m Power Output 9 600 Watts Filtering Serial Control System Input Voltage To Response Time Control Isolation 15 V DC Available to Controller Dimensions HxWxD Mounting Spec 18 3 4 NSI Microplex 50 MSEC...

Page 4: ...N A 45 48 On On Off On Off N A 49 52 Off Off On On Off N A 53 56 On Off On On Off N A 57 60 Off On On On Off N A 61 64 On On On On Off N A 65 68 Off Off Off Off On N A 69 72 On Off Off Off On N A 73...

Page 5: ...ther electrical appliances or equipment to the dimmer packs MICROPLEX INPUTS Both male and female Microplex connectors may be used for input signals Mico plex technology allows your system to be conne...

Page 6: ...g MOUNTING The NSI NRD 8000 dimmer pack may be mounted in standard EIA 10 racks The NRD 8000 is provided with two mounting flanges or ears designed for securing to the rack mounting rails Most standar...

Page 7: ...cable such as a standard 4 prong range or dryer plug be attached to the unit for portable operation The NRD 8000 is actually two 4 channel dimmers coupled together for the flexibility of eight indepen...

Page 8: ...ower in watts and E the voltage in volts 3 Always use quality 12 gauge or heavier grounded power cables for input power 4 Always use quality 18 gauge or heavier grounded power cables for output power...

Page 9: ...IGNAL CABLE 3 CHECK MAXIMUM DIMMER ASSIGNMENT AT CONSOLE 4 CHECK OUTPUT MODE OF CONTROL CONSOLE 1 TRANSMISSION LENGTH MAY BE A PROBLEM GET CONSOLE CLOSER WlTH A SHORTER CABLE TO VERIFY REMEDY MAY BE T...

Page 10: ...requires service during the warranty period NSI will repair or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any author...

Reviews: