background image

 

 
 

 
 
 
 
 
 
 
 
 

 

Channels 

5/J2 

J1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

ADDRESSING 

Each NSI dimmer pack is fully user addressable to receive any of 128 possible control 
channels. Control channels may be assigned in increments of four by addressing the NRD 
8000 to receive them. To accomplish this simply position the address select switches as 
described in the following chart. 

Note:

 New Style units have six position dipswitches where as dipswitches 1-6 are 

indicated below.  Old style units are functionally the same but offered 4 position 
dipswitches.  Internal jumpers where as J1, J2 are indicated below. 

1-4 

Off 

Off 

Off 

Off 

Off 

N/A 

5-8 

On 

Off 

Off 

Off 

Off 

N/A 

9-12 

Off 

On 

Off 

Off 

Off 

N/A 

13-16 

On 

On 

Off 

Off 

Off 

N/A 

17-20 

Off 

Off 

On 

Off 

Off 

N/A 

21-24 

On 

Off 

On 

Off 

Off 

N/A 

25-28 

Off 

On 

On 

Off 

Off 

N/A 

29-32 

On 

On 

On 

Off 

Off 

N/A 

33-36 

Off  

Off 

Off 

On 

Off 

N/A 

37-40 

On 

Off 

Off 

On 

Off 

N/A 

41-44 

Off 

On 

Off 

On 

Off 

N/A 

45-48 

On 

On 

Off 

On 

Off 

N/A 

49-52 

Off 

Off 

On 

On 

Off 

N/A 

53-56 

On 

Off 

On 

On 

Off 

N/A 

57-60 

Off 

On 

On 

On 

Off 

N/A 

61-64 

On 

On 

On 

On 

Off 

N/A 

65-68 

Off 

Off 

Off 

Off 

On 

N/A 

69-72 

On 

Off 

Off 

Off 

On 

N/A 

73-76 

Off 

On 

Off 

Off 

On 

N/A 

77-80 

On 

On 

Off 

Off 

On 

N/A 

81-84 

Off 

Off 

On 

Off 

On 

N/A 

85-88 

On 

Off 

On 

Off 

On 

N/A 

89-92 

Off 

On 

On 

Off 

On 

N/A 

93-96 

On 

On 

On 

Off 

On 

N/A 

97-100 

Off 

Off 

Off 

On 

On 

N/A 

101-104 

On 

Off 

Off 

On 

On 

N/A 

105-108 

Off 

On 

Off 

On 

On 

N/A 

109-112 

On 

On 

Off 

On 

On 

N/A 

113-116 

Off 

Off 

On 

On 

On 

N/A 

117-120 

On 

Off 

On 

On 

On 

N/A 

121-124 

Off 

On 

On 

On 

On 

N/A 

125-128 

On 

On 

On 

On 

On 

N/A 

The NRD 8000 is actually two four channel dimmers coupled together to provide eight channels 
of dimming in a single rack mountable package.  Each group of four channels has its own 
address switches. These controls channels are addressed in increments of four as outlined in the 
chart above.  

IMPORTANT: All NSI dimmer packs are shipped from the factory addressed for channels 1 -4. Units must be 

readdressed (see chart above) before being capable of receiving any other channels. 

Summary of Contents for NRD 8000

Page 1: ...NRD 8000 ADDRESSABLE DIMMER PACK OPERATION MANUAL...

Page 2: ...simplified through the abi1ity to daisy chain additional dimmer packs to an existing system This application of microplex technology makes system set up and operation easy and convenient In addition N...

Page 3: ...m Power Output 9 600 Watts Filtering Serial Control System Input Voltage To Response Time Control Isolation 15 V DC Available to Controller Dimensions HxWxD Mounting Spec 18 3 4 NSI Microplex 50 MSEC...

Page 4: ...N A 45 48 On On Off On Off N A 49 52 Off Off On On Off N A 53 56 On Off On On Off N A 57 60 Off On On On Off N A 61 64 On On On On Off N A 65 68 Off Off Off Off On N A 69 72 On Off Off Off On N A 73...

Page 5: ...ther electrical appliances or equipment to the dimmer packs MICROPLEX INPUTS Both male and female Microplex connectors may be used for input signals Mico plex technology allows your system to be conne...

Page 6: ...g MOUNTING The NSI NRD 8000 dimmer pack may be mounted in standard EIA 10 racks The NRD 8000 is provided with two mounting flanges or ears designed for securing to the rack mounting rails Most standar...

Page 7: ...cable such as a standard 4 prong range or dryer plug be attached to the unit for portable operation The NRD 8000 is actually two 4 channel dimmers coupled together for the flexibility of eight indepen...

Page 8: ...ower in watts and E the voltage in volts 3 Always use quality 12 gauge or heavier grounded power cables for input power 4 Always use quality 18 gauge or heavier grounded power cables for output power...

Page 9: ...IGNAL CABLE 3 CHECK MAXIMUM DIMMER ASSIGNMENT AT CONSOLE 4 CHECK OUTPUT MODE OF CONTROL CONSOLE 1 TRANSMISSION LENGTH MAY BE A PROBLEM GET CONSOLE CLOSER WlTH A SHORTER CABLE TO VERIFY REMEDY MAY BE T...

Page 10: ...requires service during the warranty period NSI will repair or replace at its option defective materials provided you have identified yourself as the original owner of the product to NSI or any author...