background image

 

  NRD USA

 / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310 

  PHONE

 716 773 7634 / 

FAX

 716 773 7744 / 

EMAIL

 [email protected] / 

WEB

 www.nrdllc.com 

 

  NRD Asia Pte. Ltd

 / 114 Lavender Street #08-90 CT Hub 2 Singapore 338729 

  PHONE

 +65 6679 1707 / 

EMAIL

 [email protected] / 

WEB 

www.nrdllc.com

 

 

 

 

 

 

 

 

 

 

 

        INST2035 – 2/19

 

2.0 Accessories 
 
Accessories  such  as  blowers  and  air  amplifiers  are  designed  to  be  used  with  the  P-2035  air 
ionizer to move air or nitrogen through the ionizer.  The air becomes ionized and is directed to 
the charged surface, thereby neutralizing it. 
 
2.1 Air Amplifier Model 4165 
 

 

Usage 

The  Air  Amplifier  provides  an  adjustable  mounting  bracket  to  be  used  with  the  P-2035  in 
conjunction  with  a  source  of  compressed  gas.    The  amplifier  conserves  compressor  power  by 
“amplifying” the compressed supply by as much as 13 times.  This is accomplished by entraining 
surrounding air through the ionizer, providing very efficient ionization. 
 
Assembly Procedure 

A.

 

Attach the female hose connector to the 1/4” NPT air inlet fitting.  Secure the hose 
using a 3/4” open end wrench. 

B.

 

Place the adapter ring into the recessed end of the Ion Cell.  Ensure that the bottom 
of the ring rests on the inside shoulder of the Ion Cell. 

C.

 

Engage the three thumbscrews into the threaded holes in the cell.  Do not tighten the 
screws. 

D.

 

Orient  the  air  flow  amplifier  such  that  the  cylinder  is  horizontal  and  the  air  hose 
connection is below the cylinder. 

E.

 

Insert the cell with adapter ring over the cylinder of the air flow amplifier. Engage it 
as far as it will go. 

F.

 

Secure the cell to the amplifier by tightening the three thumbscrews. 

G.

 

If the Model 4065 Air Amplifier is used, remove the dust cap from the free end of 
the air hose.  Attach the hose connector to the 1/4” NPT female outlet port of the 
filter.  Secure the hose using a 3/4” open end wrench. 

 

Maintenance 

 

To ensure maximum static removal efficiency, the cell must be replaced annually 

regardless

 

of usage.  The replacement date is 12 months after the date of manufacture. 

 

Calibration is not required. 

Model 4165 Air Amplifier 
shown with P-2035.  A 6’ 
pressure hose is also included 
(not shown). 

Summary of Contents for Staticmaster P-2035

Page 1: ...nrdllc com WEB www nrdllc com NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com 1 INST2035 2 19 Installation Operation Maintenance Staticmaster Ion Air Source Model P 2035 Contents 1 Installation 2 Accessories 3 Troubleshooting 2 3 4 ...

Page 2: ...ree thumbscrews into the threaded holes in the cell B Provide a flex hose or pipe connected to an air source that will fit the 2 32 5 9cm inside diameter of the cell C Insert the flex hose or pipe into the cell and secure it in place by tightening the three thumbscrews D Point the cell to the work area and secure it into position To ensure maximum static removal efficiency the distance between the...

Page 3: ...e female hose connector to the 1 4 NPT air inlet fitting Secure the hose using a 3 4 open end wrench B Place the adapter ring into the recessed end of the Ion Cell Ensure that the bottom of the ring rests on the inside shoulder of the Ion Cell C Engage the three thumbscrews into the threaded holes in the cell Do not tighten the screws D Orient the air flow amplifier such that the cylinder is horiz...

Page 4: ... Cause Corrective Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for evaluation Do not attempt to clean the device The Ionizer air exit needs to be closer to the charged surface 2 Air flow ...

Reviews: