background image

 

  NRD USA

 / 2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310 

  PHONE

 716 773 7634 / 

FAX

 716 773 7744 / 

EMAIL

 [email protected] / 

WEB

 www.nrdllc.com 

 

  NRD Asia Pte. Ltd

 / 114 Lavender Street #08-90 CT Hub 2 Singapore 338729 

  PHONE

 +65 6679 1707 / 

EMAIL

 [email protected] / 

WEB 

www.nrdllc.com

 

 

 

 

 

 

 

 

 

 

 

 

        INST2063 – 2/19 

2.0  

Accessories 

 
2.1  

Model 4064 Staticmaster Fan 

 

 

 
The Model 4064 is used to create airflow through the Ionizer (model P-2063).  This system 
delivers a high volume of ionized air to reduce charge on parts.  The Fan is mounted on a swivel 
base and can be placed on a flat surface or bolted to a rigid surface. 
 
2.2

 

      Model 4070  

Alpha Staticmaster® Overhead Ionizing Fan 

 

When using the Model 4070, the ideal neutralization time for the target is when it’s placed 18” to 
36” directly under the ionizing fan and increases as the distance increases 
 
 
Procedure to install a new P-2063 Ionizer: 
1.

 

Unplug AC power cord from the electrical outlet. 

             

2.

 

Align and insert ¼ turn fastener, on P-2063 ion cell, into ¼ turn receptacle, in 4064/4070 
housing, and turn clockwise to secure in place. 

 
3.

 

Plug AC power cord into an electrical outlet.

  

 

 
 

Summary of Contents for P-2063

Page 1: ...m NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com INST2063 2 19 Instruction Manual for P 2063 Ionizer Accessories CONTENTS 1 0 Model P 2063 Ionizer Page 1 2 0 Accessories Page 2 2 1 Model 4064 Fan 2 2 Model 4070 Overhead Ionizing Fan 3 0 Troubleshooting Page 3 ...

Page 2: ...a Charged parts that are placed in close proximity to the ion cell can also be effectively neutralized without the need of air movement 1 1 Installation Operation A One common method to install the P 2063 Ionizer is by using spring clips that will snap on to the posts of the Ionizer The spring clips can be attached to a mounting base There are other methods to mounting the cell but cannot involve ...

Page 3: ...me of ionized air to reduce charge on parts The Fan is mounted on a swivel base and can be placed on a flat surface or bolted to a rigid surface 2 2 Model 4070 Alpha Staticmaster Overhead Ionizing Fan When using the Model 4070 the ideal neutralization time for the target is when it s placed 18 to 36 directly under the ionizing fan and increases as the distance increases Procedure to install a new ...

Page 4: ... the expired device to NRD for proper disposal Calibration is not required 3 0 Trouble Shooting Guide Symptom Probable Cause Corrective Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for ev...

Reviews: