P-2063 Ionizer 

 

                          

                                                        

 

          Part number: P-2063-1000 (Al)         Part number: P-2063-1200 (Al)/P-2063-2200 (SST) 
                         

 

 

 

 

 

Used on 4064/4070 

 
The P-2063 Ionizer is used to neutralize static electrical charges in static sensitive operations.  
The Ionizer is normally placed in an atmospheric pressure air stream so that the airflow delivers 
ions generated by the Ionizer to the work area.  Charged parts that are placed in close proximity 
to the ion cell can also be effectively neutralized without the need of air movement. 
 
1.1  

Installation & Operation 

 

A.

 

One common method to install the P-2063 Ionizer is by using spring clips that 
will snap on to the posts of the Ionizer.  The spring clips can be attached to a 
mounting base.  There are other methods to mounting the cell, but cannot involve 
modifying the Ionizer. 

 

 

Do not alter the P-2063 in any way that may compromise the 
integrity of the source.  Do not drill holes, grind or file, tap 
holes, etc. to the P-2063. 

 

B.

 

Supply air movement through the ionizer to move the ions to the charged part.  A 
fan or compressed air/nitrogen can be used.  For parts that can be placed in close 
proximity (1”) from the grill openings, air movement may not be needed to 
effectively neutralize the charged part. 

Summary of Contents for P-2063

Page 1: ...m NRD Asia Pte Ltd 114 Lavender Street 08 90 CT Hub 2 Singapore 338729 PHONE 65 6679 1707 EMAIL sales NRDasia com WEB www nrdllc com INST2063 2 19 Instruction Manual for P 2063 Ionizer Accessories CONTENTS 1 0 Model P 2063 Ionizer Page 1 2 0 Accessories Page 2 2 1 Model 4064 Fan 2 2 Model 4070 Overhead Ionizing Fan 3 0 Troubleshooting Page 3 ...

Page 2: ...a Charged parts that are placed in close proximity to the ion cell can also be effectively neutralized without the need of air movement 1 1 Installation Operation A One common method to install the P 2063 Ionizer is by using spring clips that will snap on to the posts of the Ionizer The spring clips can be attached to a mounting base There are other methods to mounting the cell but cannot involve ...

Page 3: ...me of ionized air to reduce charge on parts The Fan is mounted on a swivel base and can be placed on a flat surface or bolted to a rigid surface 2 2 Model 4070 Alpha Staticmaster Overhead Ionizing Fan When using the Model 4070 the ideal neutralization time for the target is when it s placed 18 to 36 directly under the ionizing fan and increases as the distance increases Procedure to install a new ...

Page 4: ... the expired device to NRD for proper disposal Calibration is not required 3 0 Trouble Shooting Guide Symptom Probable Cause Corrective Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for ev...