background image

Page 3 

 

 

 

 

 

 

 

 

 

 

        INST2063 - 6/14 

2.3  

Return of Expired Devices 

 
Expired P-2063 Ionizer (12 months or older) can be returned to NRD for proper disposal 
according to “Return Shipping Instructions” on page 6 of this manual.  A Return Authorization 
(RA) is not required prior to sending a device back for disposal. 
 
 
 
 
3.0  

P-2063 Nuclecel

 Ionizer 

 
 
 
 
The P-2063 Nuclecel

 Ionizer is used to neutralize static electrical charges in static sensitive 

operations.  The Ionizer is normally placed in an atmospheric pressure air stream so that the 
airflow delivers ions generated by the Ionizer to the work area.  Charged parts that are placed in 
close proximity to the ion cell can also be effectively neutralized without the need of air 
movement. 
 
3.1  

Installation & Operation 

 

A.

 

One common method to install the P-2063 Nuclecel

 Ionizer is by using spring 

clips that will snap on to the posts of the Ionizer.  The spring clips can be attached 
to a mounting base.  There are other methods to mounting the cell, but cannot 
involve modifying the Ionizer. 

 

 

Do not alter the P-2063 Nuclecel

 in any way that may 

compromise the integrity of the source.  Do not drill holes, 
grind or file, tap holes, etc. to the P-2063 Nuclecel

 

B.

 

Supply air movement through the ionizer to move the ions to the charged part.  A 
blower, fan, or compressed air/nitrogen can be used.  For parts that can be placed 
in close proximity (1”) from the grill openings, air movement may not be needed 
to effectively neutralize the charged part. 

 

 

Summary of Contents for Nuclecel P-2063

Page 1: ...63 Nuclecel Ionizer Accessories CONTENTS 1 0 Introduction Page 1 1 1 Our Thanks 1 2 Other NRD Products 1 3 Customer Support 2 0 General Information Page 2 2 1 Safety of NRD Devices 2 2 Lease Agreement 2 3 Return of Expired Devices Page 3 3 0 Model P 2063 Nuclecel Ionizer 4 0 Accessories Page 4 4 1 Model 4064 Fan 5 0 Troubleshooting Page 5 APPENDIX Data Sheet Specifications Page 6 Safety Brochure ...

Page 2: ...or control electrostatic charges The many product configurations we offer will fit a wide field of applications Just call us with your application and we can provide a solution The electronics industry uses air ionizers to reduce product damage and loss Application of ionizers in the printing converting and graphics industries allow in process cleaning of product and faster process speeds Higher p...

Page 3: ...bject or attempt to clean the inside of the cell Mount the ion cell in a normal way by using the mounting posts of the ion cell Do not alter the ionizer in any way i e drilling holes Contact us for mounting options Review the enclosed Safety Brochure for a more detailed description of how the ionizers work where they are typically used and the general safety of NRD ionizers 2 2 Lease Agreement All...

Page 4: ...to the ion cell can also be effectively neutralized without the need of air movement 3 1 Installation Operation A One common method to install the P 2063 Nuclecel Ionizer is by using spring clips that will snap on to the posts of the Ionizer The spring clips can be attached to a mounting base There are other methods to mounting the cell but cannot involve modifying the Ionizer Do not alter the P 2...

Page 5: ...the below diagram showing the installation of the P 2063 Nuclecel Ionizer Snap in the Ionizer by aligning the Ionizer posts with the spring clips The orientation of the Ionizer does not matter since it is symmetrically designed D Re assemble the front blower housing and tighten the two phillips head screws Tightening the screws will secure the ion cell inside the fan assembly E Position the Fan As...

Page 6: ...e Action 1 Static charges are not eliminated Ion cell may be out of date and need replacement Possible oil contamination of ion cell Ions generated are being recombined before they reach the charged surface Call NRD for Ion Cell replacement Return cell to NRD for evaluation Do not attempt to clean the device Position the fan closer to the charged part 2 Fan does not turn on No power Blown fuse int...

Reviews: