Original Instructions
INSTNeutralizerAC – 11/10
The battery should be charged completely prior
to first use or if the green LED does not light
when the trigger is depressed.
Charge the battery as follows:
Remove the safety key. (Do not discard,
save to use later)
Connect the DC battery plug to the Neutral-
izer
AC battery jack.
Connect charger to AC power source.
LED indicator is Red when charging and
Green when charge is complete.
When charging is complete, disconnect
charger from AC power source and then
the Neutralizer
AC.
When LED indicator is Green the battery charger
will not over charge the battery.
Installation and Operation
Warranty Note: Failure to use clean, dry, filtered,
compressed air will VOID warranty.
Air filters remove oil, water, and other debris
from compressed air that could impede perfor-
mance of the Ionizing Blow Gun.
1.
Attach the Ionizing Blow Gun to a 1/4”
NPT hose fitting. Screw the fitting secure-
ly into the base of the handle. Use thread
sealant as needed.
2.
Connect and turn on compressed air to
Ionizing Blow Gun.
3.
Regulate the air pressure to desired level.
Do not exceed an inlet pressure of 50 psig.
4.
Remove the safety key. (Do not discard,
save to use later)
5.
Squeeze trigger to begin air flow and acti-
vate the Neutralizer
AC Ionizing Blow
Gun. Green LED on top of Ionizing Blow
Gun will be lit to verify the air ionizer cir-
cuitry is activated.
6.
Move the Ionizing Blow Gun in a slow
sweeping path, at a distance of 12”, cover-
ing the entire part. A powerful stream of
ionized air will flow over objects and
quickly neutralize electrostatic charges,
remove dust and other foreign particulate
clinging due to static attraction.
Note: Any contact, such as additional tacking,
after the surface has been cleaned and ionized
may result in re-charging the surface with static.
We recommend that you repeat the cleaning of
the part with the Ionizing Blow Gun. This en-
sures the static charges have been removed.
7.
When the Neutralizer
AC Ionizing Blow
Gun is not in use, use the ring to hang it
from a hook.
2937 Alt Boulevard / PO Box 310 / Grand Island, NY 14072-0310
PHONE
716 773 7634 /
FAX
716 773 7744 /
WEB
www.nrdinc.com
Battery jack
AC Plug
Safety key
DC Plug
LED Indicator
1/4” NPT
Trigger
Green LED
Tab
Tab
Air nozzle
Ring