5
Low-input Voltage Shutdown
When the 12 V DC power supply voltage drops below 10.5 ± 0.3 V, the
inverter will automatically shut down, and the digital display showing
“LUP”.
Low-input Voltage Alarm
When the 12 V DC power supply voltage drops below 11 ± 0.3 V, an
audible alarm will sound
,
and the digital display showing “LUP”
.
Over-heating Shut Off
When the internal temperature exceeds the regulated temperature due to
the increase of ambient temperature, the inverter will automatically shut
down
,
and the digital display showing “LCP”.
When the internal temperature drops below the surrounding air
temperature, the inverter will automatically return to normal operation.
Overload Shut Off
When the starting power exceeds the rated power, the inverter will
automatically shut down
,
and the digital display showing “OLP”.
inverter can’t automatically
restore normal operation: reset to normal
switch.
operation by using manual
Short-circuit Protection
This inverter is equipped with multiple internal fuses.
circuit state, the unit will switch to protective mode, and the digital display
showing “OPP”.
When in over current protection mode, the
When it is in short