NPower 4575000 Owner'S Manual Download Page 19

17

High battery shutdown   

15.5 ± 0.5 V DC 

Fuse

25A fuse

×

24   

Physical specifications 

Dimensions 

16.5 x 11.6 x 5.9"   
(42 x 29.5 x 15 cm) 

Weight 

25.96 lb  (11.80 kg)

9. Warranty   

One Year Limited Warranty Program 

NPower warrants this product for one year limited against any defects in 
materials or workmanship. The defective products will be replaced and 
repaired at no charge in either of one year. 
This warranty lasts for 12 months from the date of purchase at the point 
of sale to you. This warranty does not apply where the product has been 
misused, improperly installed, physically damaged or altered, either 
internally or externally, or damaged from improper use. 
NPower will repair or replace the defective product free of charge. Proof 
of purchase may be required. Warranty term is not extended if NPower 

repairs or replaces a product. NPower owns all parts removed from 

repaired products. 

Summary of Contents for 4575000

Page 1: ...Model number 4575000 TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUC...

Page 2: ...BLE OF CONTENTS 1 Introduction 1 2 Important Safety Information 1 3 Protective Features 4 4 Features 6 5 Installation 8 6 Operating Instructions 11 7 Troubleshooting 13 8 Specifications 16 9 Warranty...

Page 3: ...W It is ideal for operating household appliances on your car truck RV and boat The inverter has the safety features such as over input voltage shutdown low input voltage shut off low input voltage al...

Page 4: ...AC outlet Warning The case to the unit may become very warm under high power operation Be sure that there is at least 2 5 cm of unblocked air space around the entire surface of the inverter at all ti...

Page 5: ...o different batteries separately Caution Do not connect the unit to live AC power circuits or there may be damage to the inverter Do not connect any AC device which has its neutral conductor connected...

Page 6: ...rain water or any other liquid Do not connect the unit to any utility power distribution systems or branch circuits Do not use the inverter in temperatures over 104 F 40 C or under 32 F 0 C Failure to...

Page 7: ...matically shut down and the digital display showing LCP When the internal temperature drops below the surrounding air temperature the inverter will automatically return to normal operation Overload Sh...

Page 8: ...2 Yellow LED Indicates that the consumption of the loads is over 1000 W and the digigal display showing output power loads in kilowatts voltage 3 Green LED Indicates the digital display is showing DC...

Page 9: ...d Ventilation Openings The high speed cooling fan protects the inverter from over heating Ventilation openings should be kept clean 9 2 GFCI Protected Outlets Each GFCI has two AC outlets and is conne...

Page 10: ...C the cooler the better within this range if the ambient temperature is high the output power may not reach 4000W before the over temperature protection occur 4 0 1 F o Ventilated Leave at least 2 5...

Page 11: ...ires less power to continue operating This is referred to as the continuous load in terms of power requirements You will need to determine how much power your tool or appliance requires to start up an...

Page 12: ...polarity will cause damage to the inverter which may also void the warranty 4 Tighten the nut on each DC terminal by hand until it is snug Do not over tighten 5 Connect the AC equipment 6 When the pow...

Page 13: ...nging from 11 0 V to 15 0 V DC As the battery is used its voltage begins to fall When the inverter senses that the voltage at its DC input has dropped to the range of 10 7 11 3 V DC an audible alarm s...

Page 14: ...ystem cause the battery voltage to rise to the range of 15 0 16 0 V DC the inverter automatically shuts down readout shows OUP Caution Although the inverter incorporates protection against over voltag...

Page 15: ...w The inverter can operate while the engine is running but the normal voltage drop that occurs during starting of the engine may trigger the inverter s low voltage shutdown feature Caution Because the...

Page 16: ...m sounds Charge the battery Unit is shutdown with display showing OCP Inverter is overheated due to poor ventilation and has shut down Unplug inverter from DC socket and cool for 15 minutes Remove obj...

Page 17: ...e reading AC voltmeter used to measure output voltage resulting in an apparent reading 5 to 15 V too low Inverter s modified sine wave output requires true RMS voltmeter for accurate measurements Meas...

Page 18: ...C Output Continuous AC output power Max continuous AC output power 5 minutes 4000 W 5000 W AC output surge power 10000 W AC output voltage range 105 V 125 V AC Output frequency nominal 60 1 Hz Output...

Page 19: ...nd repaired at no charge in either of one year This warranty lasts for 12 months from the date of purchase at the point of sale to you This warranty does not apply where the product has been misused i...

Page 20: ...t been disassembled or modified without the prior authorization If you require warranty service with your product please return it to the place of purchase along with a copy of your dated proof of pur...

Reviews: