3.  Protective Features 

          Caution

Connect the unit to batteries with a normal output of 12V DC only. As 6V 

batteries voltage is too low, and a 24V battery voltage is too high which will 

damage the unit.

          Additional Safety Guidelines

            Do not insert any foreign objects into the unit outlets, vents or fan 

            openings.

            Do not expose the unit to rain, water or any other liquid.

            Do not connect the unit to any utility power distribution systems or 

            branch circuits.

            Do not use the inverter in temperatures over 104°F(40°C) or under 

            32°F(0°C).

Failure to follow these safety guidelines will result in personal injury 

and/or the damage to the unit. It may also void the warranty.

          Caution

Some chargers for small nickel-cadmium batteries can be damaged if 

connected to the unit. Do not use the unit on the following items:

Small battery-operated appliances such as flashlights, razors and 

nightlights those can be plugged directly into an AC outlet to recharge.

Certain battery chargers for battery packs used in hand power tools. 

These chargers will have a warning label indicating that dangerous 

voltages are present at the battery terminals.

Over-input Voltage Shut off

When the 12 V DC power supply voltage exceeds 15.5 ± 0.5 V, the inverter will 

automatically shut down, and the digital display showing “OUP”.

Low-input Voltage Shut off

When the 12 V DC power supply voltage drops below 10.5 ± 0.3 V, the inverter 

Summary of Contents for 4573000

Page 1: ...ST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE OWNER S MANUAL 3000W...

Page 2: ...CONTENTS 1 Introduction 2 Important Safety Information 3 Protective Features 4 Features 5 Installation 6 Operating Instructions 7 Troubleshooting 8 Specifications 9 Warranty 1 2 2 4 6 7 9 11 13 14...

Page 3: ...ff low input voltage alarm low voltage turn off resume over heating shut off overload shut off short circuit protection The unit is not designed to be waterproof It functions in ambient temperatures o...

Page 4: ...ons Warning If connected with loads of over 1000 W two sets of same size wirings must be connected to the same battery or the connected battery kit And it may damage the inverter if using one set of w...

Page 5: ...njury and or the damage to the unit It may also void the warranty Caution Some chargers for small nickel cadmium batteries can be damaged if connected to the unit Do not use the unit on the following...

Page 6: ...CP When the internal temperature drops below the surrounding air temperature the inverter will automatically return to normal operation Overload Shut Off When the starting power exceeds the rated powe...

Page 7: ...abled devices 5 Remote Switch Port Use to connect the remote ON OFF switch via a communication cable remote control switch is not included 6 Power Switch Button Turn the inverter ON or OFF 7 Digital D...

Page 8: ...unit must be operated in an area that meets the following requirements in order to operate safely and provide optimum performance Dry Don t allow water or other liquids to drop or splash on the unit C...

Page 9: ...e continuous load in terms of power requirements You will need to determine how much power your tool or appliance requires to start up and its continued running power requirements The inverter should...

Page 10: ...battery to prevent gradual discharge of battery Note This product does not include DC battery cables DC battery cables sold separately 1 When properly connected to a 12 V outlet or battery turn on the...

Page 11: ...ry charging system cause the battery voltage to rise to the range of 15 0 16 0 V DC the inverter automatically shuts down readout shows OUP Caution Although the inverter incorporates protection agains...

Page 12: ...re rated at more than 3000W overload shut down has occurred AC products are rated less than 3000W but high starting surge has caused overload shutdown Reduce load use a product with power rating less...

Page 13: ...Move the inverter to a cooler place Reduce load if continuous operation is required Restart Low voltage battery Water entered the unit Charge the battery Disconnect the inverter and wipe immediately...

Page 14: ...ment Replace battery Some chargers are not able to fully recharge a battery Make sure you use a powerful charger Power dissipation in DC cables Use shorter heavier DC cables 8 Specifications Specifica...

Page 15: ...r one year limited against any defects in materials or workmanship The defective products will be replaced and repaired at no charge in either of one year This warranty lasts for 12 months from the da...

Page 16: ...t been disassembled or modified without the prior authorization If you require warranty service with your product please return it to the place of purchase along with a copy of your dated proof of pur...

Reviews: