NPower 4572000 Owner'S Manual Download Page 5

4.

3.  Protective Features 

          Caution

Connect the unit to batteries with a normal output of 12V DC only. As 6V 
batteries voltage is too low, and a 24V battery voltage is too high which will 
damage the unit.

          Additional Safety Guidelines

Do not insert any foreign objects into the unit outlets, vents or fan openings.
Do not expose the unit to rain, water or any other liquid.
Do not connect the unit to any utility power distribution systems or branch 
circuits.
Do not use the inverter in temperatures over 104°F(40°C) or under 32°F(0°C).

Failure to follow these safety guidelines will result in personal injury 
and/or the damage to the unit. It may also void the warranty.

Certain battery chargers for battery packs used in hand power tools. 
These chargers will have a warning label indicating that dangerous 
voltages are present at the battery terminals.

Over Input Voltage Shut Off 
When the 12 volt DC power supply voltage exceeds 15.5±0.5 volts, the inverter 
will automatically shut down, and the digital display showing “OUP”.
Low Input Voltage Shut Off
When the 12 volt DC power supply voltage drops below 10.5±0.3volts, the 
inverter will automatically shut down, and the digital display showing “LUP”.
Low Input Voltage Alarm
When the 12 volt DC power supply voltage drops below 11±0.3volts, an audible 
alarm will sound, and the digital display showing “LUP”.
Over Heating Shut Off
When the internal temperature exceeds the regulated temperature due to the 

Summary of Contents for 4572000

Page 1: ...ST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE 1500W Power Inverter...

Page 2: ...CONTENTS 1 Introduction 2 Important Safety Information 3 Protective Features 4 Features 5 Installation 6 Operating Instructions 7 Troubleshooting 8 Specifications 9 Warranty 2 2 4 5 6 8 11 13 14...

Page 3: ...low input voltage shut off low input voltage alarm low voltage turn off resume over heating shut off overload shut off short circuit protection The unit is not designed to be waterproof It applies to...

Page 4: ...ns Caution Do not connect the unit to live AC power circuits or there would be damage to the inverter Do not connect any AC device which has its neutral conductor connected to ground to the unit Warni...

Page 5: ...o the unit It may also void the warranty Certain battery chargers for battery packs used in hand power tools These chargers will have a warning label indicating that dangerous voltages are present at...

Page 6: ...hen the starting power exceeds the rated power the inverter will automatically shut down and the digital display showing OLP When being in over current protection state the inverter can t automaticall...

Page 7: ...tal display is showing DC input voltage 7 Yellow LED Indicator When the power exceeds 1000W the yellow LED indicator lights and the digigal display showing output power loads in kilowatts 8 Red LED In...

Page 8: ...load in terms of power requirements You will need to determine how much power your tool or appliance requires to start up and its continued running power requirements The inverter should be connected...

Page 9: ...re Caution If there are one more AC products connecting to the inverter turn on the larger power product first 4 Tighten the nut on each DC terminal by hand until it is snug Do not over tighten 5 Conn...

Page 10: ...ge power is connected the inverter will shut down The red LED light will light The unit will shut down automatically if the inverter exceeds a safe operating temperature due to insufficient ventilatio...

Page 11: ...ery as a power source it is strongly recommended to start the vehicle every hour to recharge the battery before its capacity drops too low The inverter can operate while the engine is running but the...

Page 12: ...eplace battery Blown fuse Check and replace fuse Lose cable connections Check the connection to the battery Tighten as required AC products connected are rated at more than 1500W overload shutdown has...

Page 13: ...er used to measure output voltage resulting in an apparent reading 5 to 15V too low Inverter s modified sine wave output requires true RMS voltmeter for accurate measurements Measured inverter output...

Page 14: ...1 lb 3050g AC output frequency nominal 58 62Hz AC output waveform Modified sine wave AC output frequency nominal 5 V DC DC input voltage range 12 8 13 2V DC 0 8A at a 12V input Low battery alarm trigg...

Page 15: ...damaged or altered either internally or externally or damaged from improper use NPower will repair or replace the defective product free of charge Proof of purchase may be required Warranty term is no...

Reviews: