TURBOTEST 400

Fiber Optic Certification Test Set

User’s Guide

Noyes TurboTest 400 Specs

Provided by www.AAATesters.com

Summary of Contents for TURBOTEST 400

Page 1: ...T e s t I n s p e c t i o n TURBOTEST 400 Fiber Optic Certification Test Set User s Guide Noyes TurboTest 400 Specs Provided by www AAATesters com...

Page 2: ...400 Fiber Optic Certification Test Set User s Guide 2002 AFL Telecommunications all rights reserved T400 00 1000 Revision D 9 09 05 Speci cations are subject to change without notice T e s t I n s p e...

Page 3: ...Unauthorized repair or modi cation Misuse negligence or accident CE Information These instruments have been designed and tested to comply with the relevant sections of any applicable speci cations in...

Page 4: ...ng le 6 to create a ber name 6 to specify starting ber numbers 7 to review test results 8 to delete selected les or all les 8 to display le and ber storage statistics 8 Selecting AutoTest Rules 8 to c...

Page 5: ...Software 19 to install new software 19 Section 7 Speci cations TURBOTEST 400 Speci cations 21 Model T410 Multimode AutoTest Rules 22 multimode commercial building premises cabling standards 22 multimo...

Page 6: ...iii Figure 4 2 AutoTest Setup 2nd part of a two way test 13 Figure 4 3 AutoTest Setup 14 Section 5 Maintenance Figure 5 1 Cleaning Optical Ports 15 Figure 5 2 Removing Battery Compartment Cover 16...

Page 7: ...nt test equipment patch cords or test jumpers Always assume that optical outputs are on NOTICE The T400 contains no user serviceable parts Except for changing batteries and cleaning optical ports this...

Page 8: ...hnical or sales support please contact Noyes Customer Service Contacting Noyes Customer Service You may call Noyes Customer Service between 8 a m and 5 p m United States Eastern Time as follows Tel 80...

Page 9: ...also operate like a traditional optical power meter to measure power or loss at 850 1300 1310 and 1550 nm In addition the Main Unit functions as a stabilized light source at 850 and 1300 nm or as a 2...

Page 10: ...test wavelength Exit Key press to return to the previous menu screen AC Adapter Port this is the interface for the AC power adapter REFERENCE IS OVER 1 DAY OLD SET REFERENCE IS RECOMMENDED OK Backlig...

Page 11: ...press to turn the instrument on or off Optical Receive Port Rx2 accepts NOYES thread on modular adapter caps Optical Transmit Port Tx1 modular adapter Serial Port used for data transfer to a PC and s...

Page 12: ...nect the test jumpers to the Main and Remote Units Figure 3 1 OR Loop back AutoTest Referencing Connect the test jumper to the Main Unit Figure 3 2 Use this reference method if the Remote Unit is not...

Page 13: ...rs or numbers The default name is FILE01 1 From the MAIN MENU select FILE then NEW 2 Use the arrow keys F1 F2 and the SELECT F3 key to enter characters Use the MAIN MENU key as a backspace Press EXIT...

Page 14: ...rs can be set to any value from 1 to 999 NOTE If initial numbers are adjacent e g 11 and 12 or 101 and 102 then they will auto increment by 2 Otherwise numbers are auto incremented by 1 EXAMPLE 1 Adja...

Page 15: ...w the additional test results use the ARROW keys to navigate to the other screens Depending on the type of test either one way uni directional or two way bi directional 8 or 12 screens of test results...

Page 16: ...ndards To specify a user de ned standard scroll to USER 1 USER 2 USER 3 or USER 4 and press EDIT F1 Use the ARROW keys to highlight the parameter to be changed then use the F1 or F2 key to adjust the...

Page 17: ...following TIME In 24 hour format To change it press SELECT F3 scroll through the elds using the F1 and F2 keys and increase or decrease them using the ARROW keys Press EXIT when done DATE In day mont...

Page 18: ...g the ARROW keys highlight the parameter to be changed then use the F1 or F2 key to adjust the selected parameter 3 Press EXIT to enter parameters and return to the POWER METER screen Using the Remote...

Page 19: ...If connected to an AC adapter then AC ON is displayed If powered by alkaline batteries a life expectancy percentage value will be displayed NOTE When the battery life reaches about 5 the Main Unit wi...

Page 20: ...test Figure 4 1 NOTE Once the AutoTest reference has been set do not disconnect the test jumper from the Main or Remote Unit transmit ports Tx2 and Tx1 6 Conduct the test Press the AUTOTEST key The M...

Page 21: ...ce the loop back AutoTest reference has been set do not disconnect the test jumper from the Main Unit transmit port Tx2 6 Conduct the test Press the AUTO TEST key The Main Unit will conduct the test a...

Page 22: ...r cleaning cartridge is recommended to clean the optical ports cleaning transmit ports Tx1 Tx2 1 Remove the dust cap on the adapter refer to Figure 5 1 2 Remove two screws holding the adapter 3 Pull t...

Page 23: ...t ashes LOW BAT in the upper right corner of the AutoTest screen or when the Remote Unit low battery LED is active perform the following steps on that unit 1 Starting from the bottom remove the protec...

Page 24: ...describes WinTest 400 system requirements installation procedures and basic setup information system requirements To use WinTest 400 you need the following hardware and software A 400 MHz or faster pe...

Page 25: ...Using the supplied serial cable connect the Main Unit to an available COM Port on the PC 2 If WinTest is not running from the Windows Start Menu select Programs WinTest 400 3 From the WinTest 400 Set...

Page 26: ...alling New Main and Remote Unit Software WinTest 400 provides the ability to install new TURBOTEST 400 software via the units serial ports New TURBOTEST 400 software may contain new features new AutoT...

Page 27: ...the MAIN MENU select CONNECT TO PC OR Remote Unit Press the Power key to turn on the unit When the Tx1 Active LED is ashing press and hold the Power key again for about 4 seconds until the Ready LED...

Page 28: ...librated wavelengths 850 1300 1310 1550 nm Power measurement accuracy 25 C 0 25 dB 20 dBm 2 0 25 dB 10 dBm Length measurement range 11 dB 5 km 11 dB 20 km Length measurement accuracy 2 1 5 m Modular a...

Page 29: ...ables 50 or 62 5 m ber EN 50173 2000 3 5 1 0 75 0 3 Multimode Application Standards Rule T410 Name Total Loss 850 nm dB Total Loss 1300 nm dB Length m Delay ns 10 Mb s Ethernet 850 nm on 62 5 m ber 10...

Page 30: ...75 0 3 TIA EIA 568 B outside plant singlemode ber preliminary draft TIA 568 B OUT 0 5 0 5 0 75 0 3 ISO 11801 International Standard inside plant singlemode ber ISO 11801 0 5 0 5 0 75 0 3 EN 50173 Eur...

Page 31: ...ountry speci c line cord Polarity of Adapter Jack NOTE For connection to a PC a standard straight through serial cable is required The connector on the Turbotest 400 end must be a 9 pin male DCE Ready...

Page 32: ...k you for choosing Noyes Test Inspection 16 Eastgate Park Road Belmont NH 03220 Phone 800 321 5298 603 528 7780 Fax 603 528 2025 www AFLtele com Products Noyes Test Inspection T e s t I n s p e c t i...