background image

 

 

 

11 

 

USA 

IRL 

AUS 

GB 

NZ 

CDN 

IND 

 

Collect and dispose of the residual liquid according to all applicable laws, 
requirements and regulations. Review the liquid manufacturer’s health, safety and 
disposal warnings! 

4.  Rinse out the sprayer with the appropriate solvent or water. 
5.  Wipe off all solvent or water residue. 
6.  To store the sprayer, separate the tank and pump and store in a dry place protected 

from sunlight and freezing temperatures. 

 
Care and maintenance 

 

Observe the instructions in the section entitled “Safety”. 

After using the device 50 times or at least once a year: 
•  Disassemble the sprayer [A] and grease the piston cup washer [6]. 

(Fig. 14 -15).

 

•  Clean the spray tip [37-43] with the appropriate cleaning solvent or water. If required use a 

needle. 

(Fig. 16).

 

•  Remove the 200 mesh anti-siphon filter [35] from the end of the wand and the 100 mesh 

filter location inside the trigger valve filter house [24] and clean thoroughly with the 
appropriate solvent or water.  

(Fig. 17).

 

•  Grease the seals [6] and [11 and 30]. 

(Fig. 19 and 22)

 

•  Visually check the sprayer before each use for signs of leakage. Replace all worn parts. 

Replace the tank if any holes are observed. 

 

 

Troubleshooting 

 

Use only NOX-CRETE spare and accessory parts (you will find some in the spare 
parts container (page 2 and 3).  

 
 

 
 
 
 
 

 

Problem 

Cause 

Remedy 

No pressure builds up in 
the device 

The pump is not screwed on 
tightly. 

Screw the pump on tightly 

O-ring [11] on the pump is 
faulty.  

Replace the O-ring. 

(Fig. 19).

 

Foot valve disk [12] defective. 

Replace the foot valve. 

(Fig. 18).

 

Piston washer [6] is defective.  Replace piston washer. 

Liquid flows out of the 
pump. 

Foot valve disk [12] defective.   Clean or replace the foot valve 

disk. 

(Fig. 18). 

The sprayer does not 
spray even though 
pressure is present. 

Filters [24 and 35]

 

and / or 

spray tip [37-43] blocked. 
Pressure regulator [F] is set too 
low.  

Clean the filters or / and spray 
tip. 

(Fig. 16 +17)

 

Turn pressure regulator dial 
clockwise to increase pressure

.  

Summary of Contents for PFCS 3615 FN

Page 1: ......

Page 2: ...2 Spare Parts Piezas de repuesto Pièces de Rechange Ersatzteile ...

Page 3: ... 36 Cap nut brass 6 Piston cup washer 38 mm 37 80005 Spray tip 7 Safety valve 6 bar with gasket 38 800067 Spray tip 8 Gasket D14 x D9 7 x 2 mm 39 8001LP Spray tip 9 Funnel cover 40 8002LP Spray tip 10 Cylinder tube with gasket and valve disk 41 8003LP Spray tip 11 O ring D47 x 5 33 mm 42 8004LP Spray tip 12 Foot valve disk 43 8005LP Spray tip 13 Pressure gauge 6 bar w gasket 44 Holding rod 14 Pump...

Page 4: ...4 ...

Page 5: ...5 ...

Page 6: ...6 ...

Page 7: ...ore each application This sprayer is designed only for use in exterior applications Improper use may result in personal injury Not suitable for Flammable liquids with a flashpoint below 100 F 38 C Hydrogen peroxide or other strong oxidizers Corrosive substances acids and bases Products containing ammonia Products containing acetone Extremely viscous liquids Use with food Under no circumstances sho...

Page 8: ...ox Crete replacement and accessory parts Wear suitable protective equipment when working with hazardous substances When hand pumping or filling sprayer tank with compressed air always observe the pressure gauge to ensure the maximum spraying pressure is not exceeded Table 1 below Before filling after use and before maintenance work allow the residual pressure in the tank to dissipate completely Se...

Page 9: ...e safety valve 7 Fig 4 The pressure must dissipate Activate the trigger valve H Fig 13 The trigger valve must open and close Sprayer Preparations Observe the instructions in the section entitled Safety 1 Pull up the red button on the safety valve 7 until all excess pressure is released from the tank Fig 4 2 Press the pump handle 1 down and turn it counterclockwise 3 The pump handle is locked in pl...

Page 10: ...ipping purge the sprayer by holding the spray wand in the air before spraying and open the trigger valve until no liquid mixed with air is released 2 Begin spraying Table 2 Spray Tip Recommendation Guide Products Recommended Spray Tip Cures and Sealers 8003LP 8004LP or 8005LP Water Repellant Sealers 8003LP 8004LP or 8005LP Form Release Agents Chembeton Pro Release 8003LP All other release agents 8...

Page 11: ...nside the trigger valve filter house 24 and clean thoroughly with the appropriate solvent or water Fig 17 Grease the seals 6 and 11 and 30 Fig 19 and 22 Visually check the sprayer before each use for signs of leakage Replace all worn parts Replace the tank if any holes are observed Troubleshooting Use only NOX CRETE spare and accessory parts you will find some in the spare parts container page 2 a...

Page 12: ...equired warranty period maximum 3 years this sprayer will not exhibit any material or processing errors If defects are discovered during the warranty period Nox Crete Inc or the distributor in your area will repair the sprayer without charging for the labor or material or at the discretion of Nox Crete Inc replace the sprayer itself or its defective parts If such defects are discovered please cont...

Reviews: