2

  Changing the exhaust direction of the motor (if desired).

 Sideways:

-  Open the bottom plate and remove the filters from the ceiling unit.
-  Disconnect the cord that connects the motor to the ceiling unit.
-  Loosen the 8 screws located next to the protective grid.
-  Turn the motor with the exhaust into the desired position and screw the motor back on using the 8 screws.

3

  Changing the exhaust direction of the motor (if desired).

 Top:

A  Loosen the 6 screws on the motor cover. 
B  Turn the motor cover a quarter turn and place the motor cover back into the motor housing. Screw it back on again 

using the 6 screws. 

4

  Connect the exhaust duct to the connection nozzle by means of a hose clamp (keep in mind the length of the exhaust 

duct in case of removal, if necessary).

 

Put the plug into the wall socket.

 

Push the ceiling unit up into the build-in opening by pushing on the edges (not on the bottom plate) until you hear a 
firm click. The ceiling unit will now remain suspended in place.

5

  Drehen Sie die vier Klemmschrauben von Hand fest, um die Deckeneinheit endgültig zu befestigen. Achtung: drü-

cken Sie dabei die Dunsthaube nicht nach oben und ziehen Sie die Halteklammern nicht zu stark an, da sie sich sonst 
unnötig verbiegen. Sobald diese Klemmschrauben festgedreht sind, ist die Deckeneinheit einsatzbereit.

Removing the ceiling unit
 

6

  Before dismounting, protect the cooking plate, for example using cardboard or cloth, in case a screw or clamp is 

dropped onto it. To remove the ceiling unit, the 4 clamping screws have to be fully loosened. When these are loose, 
the ceiling unit can be taken down. Watch out: the loosened clamping springs may drop down.

Remote installation of the motor unit

7

  Take the motor unit from the ceiling unit by removing the 8 mounting screws (see (2)); use these screws again to 

mount the tube adapter to the ceiling unit. You can loosen the plugs on the motor unit.

8

  These are the possibilities of the positions the motor unit may occupy.

9

  A  Determine the location and the suspension position of the motor unit. If necessary, the exhaust direction of the  

 

  motor can be changed. The supply and exhaust pipes can be made in a 90° angle or opposite each other. 

 

B  Screw the tube adapter (6830029) to the bottom of the motor using the screws (8x 906116).

10

  Mount the suspension bracket to the motor housing. This is done by first unscrewing the screws provided from the 

motor housing. After this, place the suspension bracket onto the motor unit and screw it back on using the same 
screws. You can choose position A or position B.

11

  To mount the motor unit onto the wall, you first mark out the 4 drilling holes.

12

  To mount onto a stone wall: use the screws 906055 and the plugs 906143.

-  Drill the 4 marked-out points and place the plugs into the holes.
-  Partly screw in 2 screws in position 1 and position 2.
-  Suspend the motor unit over these 2 screws. Next, tighten the screws.
-  Now screw in the screws in position 3 and position 4.

 

To mount onto a wooden wall: use the screws 906192.
-  Partly screw in 2 screws in position 1 and position 2.
-  Suspend the motor unit over these 2 screws. Next, tighten the screws.
-  Now screw in the screws in position 3 and position 4.

 

13

  Connect the plastic exhaust (864006) onto the tube adapter using 4 screws (906116).

14

  Mount the suction and exhaust pipe to the motor unit by means of a hose clamp. Connect the plug of the cable co-

ming from the ceiling unit to the plug on the motor unit.

INSTALL THE EXHAUST DUCT