Chapter4 Setting of softwar
e
Manual of NVCM
- 19 -
parameter settings dialog. See as Figure 4-3
Figure4-4.
Motor operating parameter settings dialog
The parameters are defined as follows:
S
:
teps per Pulse equivalent ,it is number of pulses required with axial movement 1mm, This
can be calculated by lead screw pitch and motor drive segment. Such as pitch 2.5mm,2-phase
motor 8 segments, Calculation method is
。
8*200/2.5=640
:
Velocity The speed is the axial velocity, Units
,
is mm/s Recommended settings 1500.
:
Acceleration Units
,
is mm/s2 Recommended settings 200.
:
Step Pulse Step Pulse Cannot be set, it’s 2.5us in default.
:
Dir Pulse . Dir Pulse Cannot be set, it’s 2.5us in default.
Attention: The parameters for each axis is not necessarily the same
,
To select the axis,
and then set parameters. You should click “SAVE AXIS SETTINGS” After setting.
4.2.3 Port Settings