CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short
-
circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
2. START
-
UP AND INITIAL CAMERA CONFIGURATION
2.1. Description of connectors
START
-
UP AND INITIAL CAMERA CONFIGURATION
Nr
Connector Type/Color
Function
Description
1
RJ45 socket, white
Port Ethernet
100Mbps Ethernet connector
2
BNC socket, white
Video output
CVBS video output
3
ARK screw terminal
block
1. Alarm input A
Alarm input, configurable: NC or NO
2. Alarm input B
3. Alarm output A
Alarm output, NO (relay, 12VDC/24VAC 0.3A max)
4. Alarm output B
4
-
RESET button
Button to restore factory settings
5
DC2,5/5,5 socket
Power connector
Power supply, 12VDC ± 10%
1.
100 Mbps Ethernet port
2.
CVBS video output
3.
Alarm input/output block
4.
Reset button
5.
12VDC power supply connector