background image

NVIP-4DN3060H/IR-1P, NVIP-4DN3061H/IR-1P 

User’s manual (short form) ver 1.0.

 

All rights reserved © AAT Holding S.A.  

 

IMPORTANT SAFEGUARDS AND WARNINGS 

EMC (2004/108/EC) and LVD (2006/95/EC ) Directives 
 

 
CE Marking 

 

Our products are manufactured to comply with requirements of the following directives and national regulations 
implementing the directives:  
 

 

Electromagnetic compatibility EMC 2004/108/EC. 

 

Low  voltage  LVD  2006/95/EC  with  further  amendment.  The  Directive  applies  to  electrical 
equipment  designed  for  use  with  a  voltage  rating  of  between  50VAC  and  1000VAC  as  well  as 
75VDC and 1500VDC. 

WEEE Directive 2002/96/EC 

 

Information on Disposal for Users of Waste Electrical and Electronic Equipment 

 
 

This  appliance  is  marked  according  to  the  European  1000VAC  Directive  on  Waste  Electrical  and 

Electronic Equipment (2002/96/EC) and further amendments. By ensuring this product is disposed of correctly, 
you will help to prevent potential negative consequences for the environment and human health, which could 
otherwise be caused by inappropriate waste handling of this product. 
The symbol on the product, or the documents accompanying the product, indicates that this appliance may not be 
treated as household waste. It shall be handed over to the applicable collection point for used up electrical and 
electronic equipment for recycling purpose. For more information about recycling of this product, please contact 
your local authorities, your household waste disposal service or the shop where you purchased the product. 

 

RoHS Directive 2002/95/EC 

Out of concern for human health protection and friendly environment, we assure that our products 
falling  under  RoHS  Directive  regulations,  regarding  the  restriction  of  the  use  of  hazardous 
substances  in  electrical  and  electronic  equipment,  have  been  designed  and  manufactured  in 
compliance with the above mentioned regulations. Simultaneously, we claim that our products have 
been  tested  and  do  not  contain  hazardous  substances  whose  exceeding  limits  could  have  negative 
impact on human health or natural environment 

 

Information 

The device, as a part of professional CCTV system used for surveillance and control, is not designed for self 
installation in households by individuals without technical knowledge. 

 

Excluding of responsibility in case of damaging data on a disk or other devices:  

The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other devices 
during device operation. 

WARNING! 

PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN PRODUCT IN 

USER’S  MANUAL  AND  OTHER  DOCUMENTS  DELIVERED  WITH  THE  PRODUCT,  OR  IF  IT  DOES 

NOT  ARISE  FROM  THE  USUAL  APPLICATION  OF  THE  PRODUCT,    MANUFACTURER  MUST  BE 

CONTACTED UNDER THE RIGOR OF EXCLUDING THE MANUFACTURER’S  RESPONSIBILITY FOR 

THE RESULTS OF SUCH AN ACTION. 

Summary of Contents for NVIP-4DN3060H/IR-1P

Page 1: ...User s manual short form NVIP 4DN3060H IR 1P NVIP 4DN3061H IR 1P ...

Page 2: ... equipment for recycling purpose For more information about recycling of this product please contact your local authorities your household waste disposal service or the shop where you purchased the product RoHS Directive 2002 95 EC Out of concern for human health protection and friendly environment we assure that our products falling under RoHS Directive regulations regarding the restriction of th...

Page 3: ...he user s manual 5 The device should be disconnected from power sources during maintenance procedures 6 Usage of additional devices and components neither provided nor recommended by the producer is forbidden 7 You are not allowed to use the camera in high humidity environment i e close to swimming pools bath tubs damp basements 8 Mounting the device in places where proper ventilation cannot be pr...

Page 4: ... Connecting ethernet cable 9 2 4 Camera mounting 10 2 5 Starting the IP camera 11 2 6 Initial configuration via web browser 12 3 NETWORK CONNECTION UTILIZING WEB BROSWER 13 3 1 Recommended PC specification for web browser 13 3 2 Connection with IP camera via web browser 13 4 USING AND CONFIGURING 15 4 1 Remote Preview Interface 15 5 ELECTRIC CONNECTORS AND ACCESORIES 16 5 1 Connecting power supply...

Page 5: ...H IR 1P Built in LED illuminator 42 pcs LED NVIP 4DN3060H IR 1P 36 pcs LED NVIP 4DN3061H IR 1P Compression H 264 Max video processing resolution 2560 x 1440 Multi streaming compression resolution speed and quality defined individually for each video stream RTP RTSP protocol support for video transmission Post alarm functions Hardware motion detection Built in webserver camera configuration through...

Page 6: ...25 fps for 2560 x 1440 30 fps for other resolutions Multistreaming Mode 3 streams Video Compression H 264 Number of Simultaneous Connections Max 10 Network Protocols Support ONVIF 2 3 TCP IP DHCP PPPoE DDNS SMTP UPnP RTSP NTP PC Software NOVUS NMS Internet Explorer Google Chrome Opera Mozilla Firefox OTHER FUNCTIONS OSD IE browser Polish English Russian and others Motion Detection Yes Postalarm 5 ...

Page 7: ...pack all the elements back into the original box and contact your supplier for further assistance CAUTION If the device was brought from a location with lower temperature please wait until it reaches the temperature of location it is currently in Turning the device on immediately after bringing it from a location with lower ambient temperature is forbidden as the condensing water vapour may cause ...

Page 8: ... currently in Turning the device on immediately after bringing it from a location with lower ambient temperature is forbidden as the condensing water vapour may cause short circuits and damage the device as a result Before starting the device familiarize yourself with the description and the role of particular inputs outputs and adjusting elements that the device is equipped with 2 START UPAND INI...

Page 9: ...follow instruction below 1 Loosen the nut a from the main element b 2 Run power cable without RJ 45 connector though both elements Then crimp the cable with RJ 45 connector 3 Connect the cable to the hermetic connector c screw main cover b then screw the nut a WARNING Other camera connector are not hermetic User should seal connectors by himself START UPAND INITIAL IP CAMERA CONFIGURATION a b a b ...

Page 10: ... the camera with bracket on the ceiling wall with three supplied self tapping screws Loosen nut A Adjust camera position Adjust zoom and focus Tighten nut A WARNING Please note that the wall or ceiling must have enough strength to support the IP Camera WARNING In order to obtain declared degree of protection please seal the camera bracket to prevent water getting inside Furthermore when installing...

Page 11: ...era Then You can proceed to connect to the camera via web browser The recommended way to start an IP camera and perform its configuration is a connection directly to the network switch which is not connected to other devices To obtain further information about network configuration parameters IP address gateway network mask etc please contact your network administrator Connection utilising network...

Page 12: ...ropriately set PC IP address so the two devices can operate in one network subnet e g for IP 192 168 1 1 appropriate address for the camera ranges from 192 168 1 2 to 192 168 1 254 for example 192 168 1 60 It is not allowed to set the same addresses for camera and PC computer You can either set a network configuration IP address gateway net mask etc of NOVUS IP camera yourself or select DHCP mode ...

Page 13: ...hic card NVIDIA GeForce 1 GHz 4 OS Windows XP VISTA Windows 7 8 5 Network card 10 100 1000 Mb s 3 2 Connection with IP camera via web browser You have to enter camera IP address in the address bar When you connect to the camera web browser will download the applet for displaying images from the camera In Internet Explorer it may be necessary to accept an ActiveX control To do this click the right ...

Page 14: ...iveX controls not marked as safe select Enable or Prompt You can also add the camera s IP address to trusted zone and set lowest security level for it In addition when working in Windows Vista 7 8 the ActiveX applet may be blocked by Windows Defender or User account control In such case you should allow to run this applet or simply disable these functions After successful installation login window...

Page 15: ...con changes color from white to red when motion is detected Alarm icon changes color from white to red when alarm situation has occured 2 Display fluency settings It is possible to increase video display fluency by setting video buffor 0 4 seconds 3 Video size settings Fix size Zoom in Full screen Zoom in Zoom out 4 Local record Start record Snap Playback Enable disable audio USING AND CONFIGURING...

Page 16: ...f appropriate surge protectors is advised Any damages resulting from surges are not eligible for service repairs 6 RESTORING FACTORY DEFAULTS Camera allow to restore defaults via software web browser level software NMSiptool level 6 1 Restoring factory defaults by software means User can restore default settings of the IP camera except network settings To restore to default settings go to Advanced...

Page 17: ...NVIP 4DN3060H IR 1P NVIP 4DN3061H IR 1P User s manual short form ver 1 0 All rights reserved AAT Holding S A 17 NOTES ...

Page 18: ...2015 08 05 TŁ MM AAT Holding S A ul Puławska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com ...

Page 19: ...instrukcja obsługi skrócona NVIP 4DN3060H IR 1P NVIP 4DN3061H IR 1P ...

Page 20: ...g utylizacji odpadów lub sklepem gdzie nabyto produkt Dyrektywa RoHS 2002 95 EC Informacja dla użytkowników dotycząca ograniczenia użycia substancji niebezpiecznych w sprzęcie elektrycznym elektronicznym W trosce o ochronę zdrowia ludzi oraz przyjazne środowisko zapewniamy że nasze produkty podlegające przepisom dyrektywy RoHS dotyczącej użycia substancji niebezpiecznych w sprzęcie elektrycznym i ...

Page 21: ...orskich urządzenie musi być odłączone od zasilania 6 Nie wolno stosować żadnych dodatkowych urządzeń lub podzespołów nie przewidzianych i nie zalecanych przez producenta 7 Nie wolno używać kamery w środowisku o dużej wilgotności np w pobliżu basenów wanien w wilgotnych piwnicach 8 Nie należy instalować tego urządzenia w miejscu gdzie nie można zapewnić właściwej wentylacji np zamknięte szafki itp ...

Page 22: ... 4 Montaż kamery 10 2 5 Uruchomienie kamery IP 11 2 6 Konfiguracja parametrów przy użyciu przeglądarki internetowej 12 3 POŁĄCZENIA SIECIOWE ZA POMOCĄ PRZEGLĄDARKI WWW 13 3 1 Zalecana konfiguracja komputera PC do połączeń przez przeglądarkę WWW 13 3 2 Połączenie sieciowe z kamerą IP za pomocą przeglądarki WWW 13 4 INTERFEJS WWW PRACA Z KAMERĄ 15 4 1 Widok zdalnego podglądu 15 5 POŁĄCZENIA ELEKTRYC...

Page 23: ...eni 42 diod LED NVIP 4DN3060H IR 1P 36 diody LED NVIP 4DN3061H IR 1P Wbudowany webserwer kompresja i transmisja przez sieć wideo i audio w czasie rzeczywistym Kompresja H 264 Rozdzielczość przetwarzania wideo 2560 x 1440 Możliwość definiowania kompresji rozdzielczości prędkości i jakości dla każdego strumienia Przesyłanie wideo w standardzie RTP RTSP Funkcja po alarmu nagrywanie wideo w formacie A...

Page 24: ...rzania 25 kl s dla 2560 x 1440 30 kl s dla pozostałych rozdzielczości Tryb wielostrumieniowy 3 strumienie Kompresja wideo H 264 Liczba jednoczesnych połączeń sieciowych maks 10 Obsługiwane protokoły sieciowe ONVIF 2 3 TCP IP DHCP PPPoE DDNS SMTP UPnP RTSP NTP Programy na PC NOVUS NMS Internet Explorer Google Chrome Opera Mozilla Firefox POZOSTAŁE FUNKCJE Menu ekranowe w oknie przeglądarki języki p...

Page 25: ... uszkodzony w transporcie należy spakować zawartość z powrotem do oryginalnego opakowania i skontaktować się z dostawcą UWAGA Jeżeli urządzenie przyniesione zostało z pomieszczenia o niższej temperaturze należy odczekać aż osiągnie temperaturę pomieszczenia w którym ma pracować Nie wolno włączać urządzenia bezpośrednio po przyniesieniu z chłodniejszego miejsca Kondensacja zawartej w powietrzu pary...

Page 26: ...znych oraz elementów regulacyjnych 1 Wyjście wideo BNC 2 Wejście audio MIC 3 Złącze zasilania kamery 12VDC 4 Port Ethernet 100 Mb s hermetyczne gniazdo RJ 45 2 2 Ustawienia ostrości i ogniskowej Opcja dostępna tylko dla kamery NVIP 4DN3061H IR 1P Aby ustawić ostrość i ogniskową należy 1 Zdjąć daszek i odkręcić osłonę 2 Dokonać regulacji przybliżenia i ostrości 3 Przykręcić osłonę i założyć daszek ...

Page 27: ...a instrukcją 1 Odkręcić nakrętkę a od głównego elementu zabezpieczającego b 2 Poprowadzić kabel sieciowy bez końcówki przez oba elementy Po przełożeniu kabla zacisnąć końcówkę RJ 45 3 Podłączyć kabel do gniazda hermetycznego c przykręcić główną osłonę b a następnie nakrętkę a Uwaga Pozostałem złącza kamery nie są hermetyczne Użytkownik powinien zapewnić ich szczelność we własnym zakresie URUCHAMIA...

Page 28: ... następnie zamocować uchwyt kamery przy użyciu załączonych kołków i wkrętów Poluzować nakrętkę A Dokonać regulacji położenia kamery Dokonać regulacji ogniskowej oraz ostrości odpowiednimi dźwigniami dotyczy modelu NVIP 4DN3061H IR 1P Dokręcić nakrętkę A Uwaga Należy zwrócić szczególną uwagę aby powierzchnia do której mocowany jest uchwyt i kamera miała odpowiednią nośność Uwaga W celu zapewnienia ...

Page 29: ...era PC lub laptopa w wydzielonym przełączniku sieciowym do którego nie ma podłączonych innych urządzeń W przypadku zasilania z zewnętrznego zasilacza wystarczy zastosować dowolny przełącznik sieciowy lub kabel podłączony bezpośrednio do komputera W celu uzyskania danych potrzebnych do konfiguracji sieci adres IP brama maska sieci itd należy skontaktować się z administratorem sieci w której urządze...

Page 30: ... IP kamery 192 168 1 200 jako adres IP komputera PC możemy ustawić adres z zakresu 192 168 1 0 192 168 1 254 np 192 168 1 60 Niedopuszczalne jest ustawianie adresu komputera takiego samego jak adres kamery Wykorzystując połączenie przez przeglądarkę internetową Internet Explorer lub oprogramowanie NMS należy ustawić docelową konfigurację sieciową adres IP maskę sieci bramę serwery DNS lub włączyć ...

Page 31: ...czości 2560 x 1440 dla 25kl s 1 Procesor Intel Core i3 3 GHz lub wyższy 2 Pamięć RAM min 4 GB 3 Karta grafiki NVIDIA GeForce 1 GHz 4 System operacyjny Windows XP VISTA Windows 7 8 5 Karta sieciowa 10 100 1000 Mb s 3 2 Połączenie sieciowe z kamerą IP za pomocą przeglądarki WWW W pasku adresu przeglądarki WWW należy wpisać adres IP kamery Jeśli podany adres jest prawidłowy i docelowe urządzenie jest...

Page 32: ...znaczonych jako bezpieczne do wykonywania należy ustawić Włącz lub Monituj Można również dodać adres IP kamer do strefy Zaufane witryny i ustawić dla tej strefy niski poziom zabezpieczeń Dodatkowo w przypadku pracy w systemie Windows Vista 7 i 8 możliwe jest zablokowanie apletu ActiveX przez Windows Defender i Kontrolę konta użytkownika W takim przypadku należy zezwolić na uruchamianie dodatku lub...

Page 33: ...iu ruchu ikona zmienia kolor z białego na czerwony 2 Ustawienia płynności wyświetlania Aby uzyskać płynny podgląd obrazu przy słabym połączeniu sieciowym można ustawić bufor obrazu w zakresie 0 4s 3 Ustawienia rozmiaru obrazu Dopasuj rozmiar Przybliż Pełny ekran Aktualny rozmiar Oddal 4 Lokalne nagrywanie Rozpocznij nagrywanie Zrób zdjęcie Odtwarzanie Włącz wyłącz audio INTERFEJS WWW PRACA Z KAMER...

Page 34: ...EŃ FABRYCZNYCH KAMERY Kamery IP firmy NOVUS umożliwiają resetowanie ustawień programowo z poziomu przeglądarki programowo z poziomu programu NMSiptool 6 1 Programowe przywracanie ustawień fabrycznych kamery IP z poziomu przeglądarki Przywracanie ustawień fabrycznych kamery IP powoduje przywrócenie wszystkich domyślnych ustawień kamery Kamera zostanie ponownie uruchomiona po ok 30 sekundach Opcja d...

Page 35: ...NVIP 4DN3060H IR 1P NVIP 4DN3061H IR 1P Skrócona instrukcja obsługi wer 1 0 Wszelkie prawa zastrzeżone AAT Holding S A 17 NOTATKI ...

Page 36: ...2015 08 05 TŁ MM AAT Holding S A ul Puławska 431 02 801 Warszawa Polska tel 22 546 07 00 faks 22 546 07 59 www novuscctv com ...

Reviews: