NVIP
-
3SD
-
8200/30
Quick start guide
ver.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
11
2.3. Mounting the camera
In order to obtain declared degree of protection please seal the mounting place additionally with
appropriate sealing mass, paying special attention to mounting holes.
CAUTION!
Declared degree of protection of the camera concerns to it case and does not include the
possibility penetration of moisture through connecting cables. Securing cables is a responsibility
of person who install the camera. The manufacturer is not responsible for any injury, damage of
the camera caused by any failure above
-
mentioned duty, what also means they are not subject to
warranty repairs.
CAUTION!
Due to safety reasons, maximum load capacity of surface shouldn
’
t be less than 25kg.
In order to successfully mount a camera, please follow the procedure below:
•
Put the bracket to the wall in a desired mounting place (with cable hole). Taking the bracket
’
s
base screw holes as a pattern, mark future drilling holes for screws using a punch.
•
Drill 4 holes in accordance with previously done markings, insert the expansion plugs into the
holes.
•
Screw the muff into the bracket and lock the muff with the locking screw.
•
Thread the wires through the hole in the muff of bracket.
•
Attach the camera to the muff in bracket, tighten the three bolts to fix the bracket and camera
and then hook the safety cord in the bracket
•
By using the description of the terminals from the previous chapter and the appropriate
accessories, connect required signal and power supply cables.
WARNING!
Connection the power cable to the camera must be performed after disconnecting the power
source. Power can be on only after the camera is fully mounted.
•
Put the excess cable back into the bracket.
•
Screw on the camera with the bracket to the wall.
After the above steps the camera is ready to work
START
-
UP AND INITIAL CAMERA CONFIGURATION