5.4 Connecting service BNC
In order to connect the service BNC connector located at the base of the camera, in the "stream" tab
choose the video format, which is supported BNC connector. After saving the settings, make sure that
your configuration streams, BNC is active.
6. RESTORING FACTORY DEFAULTS
NOVUS IP cameras allow to restore defaults via:
•
software (web browser level) resetting the camera settings
•
hardware (using reset) restores factory defaults.
6.1. Restoring software factory defaults
Factory software default restores default settings of the IP camera except network settings (optional).
The camera re
-
starts then, taking about one minute to complete. Option to restore the factory default is
described in
SETUP>FACTORY DEFAULT
tab.
6.2. Restoring hardware factory defaults in IP cameras
In order to restore factory defaults for the camera please follow the instructions:
•
press the
RESET
button and hold on for 10 seconds
•
release button
•
log on after approx. 1 minute using default IP address (http://192.168.1.200) and default user name