Novus NV-IR60/150LED User Manual Download Page 2

NV-IR60/150LED 

- User’s manual ver. 1.2 

All rights reserved © AAT Holding S.A. 

 

 

 

EMC (2004/108/EC) and LVD (2006/95/EC ) Directives 

 

CE Marking

 

 

Our  products  are  manufactured  to  comply  with  the  requirements  of  the  following  directives  and 
national regulations implementing the directives:  
 



Electromagnetic compatibility EMC 2004/108/EC. 



Low voltage LVD 2006/95/EC with further amendment. The Directive applies to electrical 
equipment designed for use with a voltage rating of between 50VAC and 1000VAC as well 
as 75VDC and 1500VDC. 

 

WEEE Directive 2002/96/EC 

Information on Disposal for Users of Waste Electrical and Electronic Equipment 
 

This  appliance  is  marked  according  to  the  European  Directive  on  Waste  Electrical  and  Electronic 
Equipment  (2002/96/EC)  and  further  amendments.  By  ensuring  this  product  is  disposed  of  correctly, 
you will help to prevent potential negative consequences for the environment and human health, which 
could otherwise be caused by inappropriate waste handling of this product. 

The symbol on the product, or the documents accompanying the product, indicates that this appliance 
may  not  be treated  as  household  waste.  It  shall  be  handed  over  to the  applicable  collection  point  for 
used  up  electrical  and  electronic  equipment  for  recycling  purpose.  For  more  information  about 
recycling of this product, please contact your local authorities,  your household waste disposal service 
or the shop where you purchased the product. 

 
 

RoHS Directive 2002/95/EC 

 
Out of concern  for human  health protection and  friendly environment, we assure that our 
products falling under RoHS Directive regulations, regarding the restriction of the use of 

hazardous substances  in electrical  and electronic equipment, have been designed and  manufactured in 
compliance  with  the  above  mentioned  regulations.  Simultaneously,  we  claim  that  our  products  have 
been  tested  and  do  not  contain  hazardous  substances  whose  exceeding  limits  could  have  negative 
impact on human health or natural environment. 
 
 

Information 

 
The device, as a part of professional  CCTV system used  for surveillance and control,  is  not designed 
for self installation in households by individuals without technical knowledge. 
 
The manufacturer is not responsible for defects and damages that result from improper or inconsistent 
with user’s manual installation of the device in the system. 

INFORMATION 

Summary of Contents for NV-IR60/150LED

Page 1: ...user s manual NV IR60 150LED...

Page 2: ...that this appliance may not be treated as household waste It shall be handed over to the applicable collection point for used up electrical and electronic equipment for recycling purpose For more info...

Page 3: ...manual and read all the safety and operating instructions before starting the device 2 Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necess...

Page 4: ...epair or upgrade the equipment himself All maintenance actions and repairs should be conducted only by qualified service personnel 13 Unplug the illuminator from the power source immediately and conta...

Page 5: ...futures of IR iluminator NV IR60 150LED High efficiency cooling structure Weatherproof enclosure Adjustable IR LED intensity Adjustable visible light sensor sensitivity High Power LED IR range up to 1...

Page 6: ...20 pieces of High Power LEDs Range 150 m possibility to increase up to 210m Angle 60 possibility to increase up to 180 Wavelength 850nm INSTALLATION PARAMETERS Dimensions mm 127 W x 205 H x 135 L Wei...

Page 7: ...ll holes Drill holes using markings Using mounting screws from the package attach the fixing bracket to the ceiling wall Gently screw the illuminator to the fixing bracket using 2 screws and 2 small p...

Page 8: ...arameters are in accordance with those specified by the producer in the camera technical datasheet Therefore it is forbidden to supply the illuminator from power sources with their parameters unknown...

Page 9: ...LED on DC 0V IR LED off DC 3V 3 3V LED Input states DC 0V IR LED on DC 3V 7 5V IR LED off 5 2 Adjusting the intensity of IR LED If want to change the intensity of the IR light open the cover at the b...

Page 10: ...2017 03 15 PR MK TF v1 2 AAT Holding S A ul Pu awska 431 02 801 Warszawa tel 22 546 0 700 fax 22 546 0 719 www novuscctv com...

Page 11: ...instrukcja obs ugi NV IR60 150LED...

Page 12: ...niniejszego produktu nale y skontaktowa si z przedstawicielem w adz lokalnych dostawc us ug utylizacji odpad w lub sklepem gdzie nabyto produkt Dyrektywa RoHS 2002 95 EC Informacja dla u ytkownik w d...

Page 13: ...ator w i u ytkownik w musz by realizowane zgodnie z opisem zawartym w instrukcji 5 W czasie czynno ci konserwatorskich urz dzenie musi by od czone od zasilania 6 Nie wolno stosowa adnych dodatkowych u...

Page 14: ...w ocznie od czy o wietlacz od r d a zasilania i przewod w sygna owych oraz skontaktowa si z serwisem w nast puj cych przypadkach Uszkodzenia przewodu zasilaj cego lub wtyczki tego przewodu Przedostani...

Page 15: ...NV IR60 150LED wysoka efektywno struktury ch odz cej obudowa odporna na warunki pogodowe regulowana intensywno wiecenia regulowana czu o czujnika wiat a widzialnego diody LED wysokiej mocy zasi g do 1...

Page 16: ...IR r d o wiat a 20 diod LED du ej mocy Zasi g 150 m z mo liwo ci zwi kszenia do 210m K t wiecenia 60 z mo liwo ci zwi kszenia do 180 D ugo fali 850nm PARAMETRY INSTALACYJNE Wymiary mm 127 szer x 205...

Page 17: ...na wkr ty mocuj ce Wywierci otwory na wkr ty mocuj ce Przykr ci uchwyt mocuj cy do powierzchni sufitu ciany za pomoc wkr t w do czonych do zestawu Delikatnie przykr ci o wietlacz do uchwytu mocuj cego...

Page 18: ...ania Uwaga O wietlacz nale y zasila ze r de o odpowiednim napi ciu i wydajno ci pr dowej Zastosowanie r d a zasilania o nieodpowiednich parametrach mo e skutkowa nieprawid ow prac urz dzenia lub jego...

Page 19: ...ametry LED Output IR LED w czony DC 0V IR LED wy czony DC 3V 3 3V Parametry LED Input DC 0V IR LED w czony DC 3V 7 5V IR LED wy czony 5 2 Regulacja intensywno ci wiecenia diod Aby zmieni intensywno wi...

Page 20: ...2017 03 15 PR MK TF v1 2 AAT Holding S A ul Pu awska 431 02 801 Warszawa tel 22 546 0 700 fax 22 546 0 719 www novuscctv com...