USERS MANUAL
NR2310-O/G
REVISION
H
DATE
7/17/20
Page #:
14 of 21
www.novuspower.com
Rear Panel
STA TU S
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
CH 8
CH 9
CH 1 0
Channel 1 through 10
– BNC
Output from each of the ten channels: 10Mhz, 1 Vr
ms, 50Ω BNC connectors.
Each output is fault and electrostatic discharge protected. Each output is
independent and any output can be faulted for an indefinite period of time with no
permanent damage.
Each output is connected to a monitor circuit that detects a local fault on the
output. The fault status is indicated on the front panel and on the LCD when in
the channel status mode. The fault status and the protection on each output
facilitates installation and helps prevent damage during installation. A channel
fault will not activate an ALERT state and the status relay will not be opened.
Alert - BNC
Connects to the status relay. Contacts rated at 20 VDC/VAC, 0.5 Amps. Contacts
are closed during normal operation. Open relay indicates failure.
Antenna - SMA
SMA female antenna connection. Provides internal 3.3VDC power at 25mA max.
The Novus NA103A pole mount antenna or the Novus NA106 magnetic mount
antenna are recommended for optimal performance.