N1500FT Flow Indicator 

NOVUS AUTOMATION 

8/8 

SPECIFICATIONS 

DIMESIONS: ............................................ 48 x 96 x 92 mm (1/16 DIN) 

 ............................................................ Approximate Weight: 242 g 

PANEL CUTOUT: .................................. 45.5 x 93 mm (+0.5 -0.0 mm) 
POWER SUPPLY: ..................... 100 to 240 Vac/dc (±10 %), 50/60 Hz 

Optionally: ..........................................................  24 Vdc/ac ±10 % 

 Maximum Consumption: ....................................................  7.5 VA 

ENVIRONMENTAL CONDITIONS

Operation Temperature: ...............................................  5 to 50 

°

Relative Humidity: ...................................... 80 % max. up to 30 ºC 

For temperatures above 30 °C, reduce 3% by °C 

Internal use; Category of installation II, Degree of pollution 2; 

altitude < 2000 m 

INPUTS 
 

4-20 mA: ......................................... Accuracy: ± 0.2% of full scale 

 

Dry Contact: ........................................... Frequency: 0.1 to 10 Hz 

 

Pulse (Tension, NPN or PNP): ........ Frequency: 0.1 to 50000 Hz 

 

 ........................................................... Amplitude: from 4 V to 24 V 

 

 ........................................................ Accuracy: ± 30 ppm @ 25 °C 

 

Magnetic Pickup: ........... Frequency: 0.1 to 8000 Hz @ 30 mVpp 

 

 ........................................................ 0.1 to 50000 Hz @ 250 mVpp 

 

 ................................................ Amplitude: from 30 mVpp to 5 Vpp 

 

 ........................................................... Accuracy: ± 0.1 % @ 25 °C 

OUTPUTS
 

4-20 mA: ..............................................  550 Ω max., 10000 levels 

 

 ........................................................................ Isolation: 250 Vrms 

 

Pulso: .............................................. Maximum frequency: 100 Hz 

 

 ....................................................................... Voltage: 0 to 30 Vdc 

 

 ............................................................... Maximum current: 15 mA 

 

 ........................................................................ Isolation: 250 Vrms 

OUTPUT RELAYS
 

ALM1 and ALM2: ..........................................................................  

 

 ................................ SPDT: 3 A / 240 Vac (3 A / 30 Vdc resisitive) 

 

ALM3 and ALM4: ..........................................................................  

 

 ....................... SPST-NA: 1.5 A / 250 Vac (3 A / 30 Vdc resisitive) 

ELECTROMAGNETIC COMPATIBILITY: ...........................................  

 ........................................ EN 61326-1:1997 and EN 61326-1/A1:1998 
SAFETY: .......................... EN61010-1:1993 and EN61010-1/A2:1995 
 

Connections suitable for fork-type terminals 6.3 mm. 

 

PROTECTION:  ................................................................................. IP65 

 

FRONT PANEL:  ............................................. UL94 V-2 polycarbonate 

 

HOUSING:  ................................................................ ABS+PC UL94 V-0 

 

Operation is started three seconds after connection to 

power supply. 

IDENTIFICATION 

N1500FT - 

4R - 

485 - 

24V 

A:  Indicator model: 

N1500FT 

B:  Output relays: 

Nothing shown  (basic version with two SPDT relays); 
4R   

 

 

(version with two additional SPST relays); 

C:  Digital Communication: 

Nothing shown  (basic version with no serial communication); 
485  

 

 

(version with RS485 serial, Modbus protocol) 

D:  Power Supply: 

Nothing shown  (basic version, power supply of 100 to 240 Vac); 

 

24V  

 

 

(version with power supply of 24 Vdc/ac). 

 
 

SAFETY INFORMATION 

Any control system design should take into account that any part of 

the system has the potential to fail. This product is not a protection or 

safety device and its alarms are not intended to protect against 

product failures. Independent safety devices should be always 

provided if personnel or property are at risk. 
Product performance and specifications may be affected by its 

environment and installation. It’s user’s responsibility to assure 

proper grounding, shielding, cable routing and electrical noise 

filtering, in accordance with local regulations, EMC standards and 

good installation practices. 

SUPPORT AND MAINTENANCE 

This product contains no serviceable parts inside. Contact our local 

distributor in case you need authorized service. For troubleshooting, 

visit our FAQ at m 

www.novusautomation.com

LIMITED WARRANTY AND  LIMITATION OF 

LIABILITY 

NOVUS warrants to the original purchaser that this product is free from 

defects in material and workmanship under normal use  and service 

within one (1) year from the date of shipment from factory or from its 

official sales channel to the original purchaser. 
NOVUS liability under this warranty shall not in any case exceed the 

cost of correcting defects in the product or of supplying replacement 

product as herein provided and upon the expiration of the warranty 

period all such liability shall terminate. 
For complete information on warranty and liability limitations, check 

appropriate section in our web site: 

www.novusautomation.com

 

Summary of Contents for N1500FT

Page 1: ...ays With pulse flow input totalization will continue even if the input rate is below the minimum rate required Instantaneous flow rate indication will be zero whenever there is a time lapse of 10 seco...

Page 2: ...maximum values of instantaneous flow rate These values can be viewed on the first screen of the main cycle by pushing and respectively The key can be set to zero maximum and minimum values FEEDER The...

Page 3: ...this key for more than 10 seconds inside the main cycle the 8 digit serial number will be shown on both displays FUNCTION OPERATION METHOD Go to the next cycle Press for more than 3 seconds Go to nex...

Page 4: ...t from off and 1 Error BLA3 Block Alarm 3 A3t1 Alarm 3 Timer 1 Visible only if Fva3 is different from off A3t2 Alarm 3 Timer 2 Fva4 Function Alarm 4 Selection of Function Alarm 4 off 1 Error Lo x1 and...

Page 5: ...ion applies quadratic function on the input signal within the limits programmed in inLL and inkL Table 7 Input setup cycle keys 1 Special application of alarm outputs When an alarm is set as Feeder an...

Page 6: ...dard current close to 20 mA will be applied Measure current in mA and enter it on this screen rstr Restore Restores factory calibration Pa x Password Change Changes user password Prot Protection Prote...

Page 7: ...ster The indicator takes broadcast type commands addresses to all network instruments For this type of command the indicator does not send any reply or acknowledgement FEATURES Signals compatible with...

Page 8: ...Communication Nothing shown basic version with no serial communication 485 version with RS485 serial Modbus protocol D Power Supply Nothing shown basic version power supply of 100 to 240 Vac 24V vers...

Reviews: