Due  to  product  specificity  we  recommend  installation 
of  the cabin  by  authorized  installation  service.  Current 
list  of  authorized  service  points  is  available  on  our 
website www.novoterm.pl or at:

 

801 144 200

 

NOTE: 

If  you  decide  to  install  the  cabin  yourself,  we  would  like  to  advise  that  due  to  safety  reasons 

 plumbing  and  electrical  installation  of  the  device  must  be  performed  by  a  qualified  plumber  or  licensed 
electrician.  Those  systems  must  be  executed  in  compliance  with  applicable  laws  and  regulations.  Incorrect 
installation may cause cabin damage!

 

B E FORE I NS TA L LA TI O N MA KE  S URE  THA T:

 

1.  

1.  The  place  where  the  cabin  is  to  be  installed 
has  been  prepared  as  shown  on  the  drawing 
(fig. 1).

 

2.  

Water  connection  is  ½’’  and  together  with  the 

valves  does  not  stick  away  from  the  wall  further 
than 30 mm. 

3.  

The  prepared drain  hole  is  50mm in  diameter  and 
is  adapted  to  standard  rubber  reducers  available 
on the market. The set does not include a reducer. 

4.  

The  hot  water  temperature  is  not  higher  than  

65°C.  Higher  water  temperature  may  causa 
faster wear of plumbing elements of the cabin. 

 

5.  

The  plumbing  system  has  been  flushed  and 

equipped  with  angle  valves  with  mechanical 
water filters. 

6.  

Static  pressure  in  the  water  supply  system  does 

not  exceed  4.5  bar.    For  safety  reasons 
we  recommend  installation  of  pressure  reducer 
regardless  of  the  measurement  results 

– 

temporary  pressure  fluctuations  are  possible 
even if it is not shown by a measurement. 

7.  

W e   re c o mme nd   c o nne c t i ng   t he   c a b i n  t o   t he  

mu ni c i p a l   w a t e r  ma i ns ,   a   w a t e r  s t o ra g e  

he a t e r  o r  he a t e r  w it h  e l e c t ro ni c  t emp e ra t ure  

c o nt ro l .  

D o   n o t   c on n e c t   t he   c ab i n   to   a  

h y d r a ul i c  

 i n s t an t a n eo u s   wa t e r   h e a t er.  

 

   

F o r  s o me   f unc t i o ns   s uc h  he a t e r  ma y  no t   t ur n  

o n  o r  w a t e r  ma y  no t   re a c h  t he   t e mp e ra t ure  

d e s i re d . 

8.  

 Electricity  connection  or  electrical  socket  are 

placed  at  the  height  preventing  water  access  or 
ensuring that it is resistant to  water ingress.  The 
terminal  box  or  socket  must  be  at  least  IP45 
water  resistant.  Cabins  equipped  with  grounding 
cable  must  be  permanently  connected  to  the 
electrical  system.  Electrical  system  must  be 
compliant with PN-EN-60335-1  standard. 

9.  

The  supply  system  is  equipped  with  a  30  mA 

residual  current  circuit  breaker  with  contact 
spacing minimum 3 mm. 

1 0.  

The  supply  voltage  is  compliant  with  the 

parameters  set  out  on  the  rating  plate  and 
protection is minimum 1A. 

1 1.  

The  room  where  the  cabin  is  to  be  installed  is 

equipped  with  working  and  efficient  ventilation 
system. 

1 2.   The  place  of  cabin  installation  has  level  surface 

at even level with the remaining part of the room, 
and level vertical walls.

 

C o mp l i a nc e   w i t h  t he   ab o ve   re q ui re me nt s   i s   ne c e s s a ry  f o r  c o rre c t   i ns ta l l a t i o n  a nd   us e  o f   t he   ca b i n

 

tuluza 2.indd 2 

2014-09-02 08:36:21 

 

I N ST AL L ATI O N

 

M AN U AL

 

H Y D R O M A S S A G E   C A B I N

 

T U LU ZA

 

Summary of Contents for Kerra Tuluza

Page 1: ......

Page 2: ...in the water supply system does not exceed 4 5 bar For safety reasons we recommend installation of pressure reducer regardless of the measurement results temporary pressure fluctuations are possible...

Page 3: ...ater temperature 55 65 C Recommended cold water temperature 10 20 C Cabin size 120 5 x 80 5 x 217 cm TECHNICAL PARAMETERS space for the cabin space that must remain free after the cabin installation e...

Page 4: ...hot water from the water system to the cabin not provided in the set Hose parameters should be as follows x length of supply hoses should be selected according to individual needs LIST OF COMPONENTS N...

Page 5: ......

Page 6: ...fil e 1 H j et 5 12 U shape cross secti on seal 2 I door handl e 2 13 fixed front gl ass 1 J sho wer set 1 14 door si de seal 2 K shelf 1 15 door gl ass 1 L power suppl y 1 16 m agneti c seal 2 M hi n...

Page 7: ...f any dirt We recommend to wait about 24 hours after the cabin installation for the silicone to bind Openings for the drainage in the shower tray are standard size If necessary you may use different d...

Page 8: ...X X N...

Page 9: ......

Page 10: ...tuluza 2 indd 9 2014 09 02 08 36 24...

Page 11: ...tuluza 2 indd 10 2014 09 02 08 36 24...

Page 12: ......

Page 13: ...EH...

Page 14: ...EH...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...Cables are marked with labels Connect to each other only those cables which are marked with the same label Connecting hoses and drainage reducer are not provided in the set...

Page 20: ...licone binds check if the cabin is waterproof Any leaks should be removed before it is positioned by the wall Connect the cabin to the electrical system only after you have checked if it is waterproof...

Page 21: ...down decreases the water flow To increase the water tempe rature turn the handle left to decrease it turn it right The massage function in the cabin is provi ded by horizontal massage jets They use n...