3.3 General information

For horizontal mounting of the transducer with an electrical

range longer than 1000 mm it is advisable to support or

attach the rod at the end (models with internal thread on 

rod end recommended).

For the area of the cable and lead wire please take care 

that enough space is available. The minimum bending

radius must be observed and sharp edges must be

avoided. 

3.4 Welding

  When welding on the cylinder or adjacent components, 

  the following must be observed to avoid any damage 

 to the sensor or seals by welding current:

 - preferably, the transducer should be removed before welding

 - with a built-in sensor, all sensor connections must be 

 disconnected during welding and the grounding connection of the   

 welding unit must not be attached to the cylinder or the piston rod.

4 EMC, Machine ground and cable shielding

4.1 Mobile hydraulics with installation in cylinder

  The EMC measurements were conducted in a reference 

  cylinder. The EMC properties can however deviate when 

  using different cylinders. In critical applications it is therefore 

  recommended to submit the complete system to an own EMC testing.

For correct operation and to compensate potential differences, the 

cylinder must be connected to machine ground. This is usually 

given by the mechanical contact of the cylinder with the other 

parts of the machine.

If the cylinder is insulately connected to the machine, a separate 

grounding must be ensured e.g. by a grounding strap.

The built-in transducer is shielded sufficiently by the metallic 

hydraulic cylinder. Therefore, the transducer does not provide a 

separate shielding via the connector or cable outlet.

CAN interface: If a shielded cable is used between the transducer 

and the controller, the cable shield must be connected to GND. 

Page 3

3.3 一般情報

 

電気測定範囲が 1000mm を超える変位トランスデューサを水平に設置する場合は、ロッド
の端を支持することをお勧めします(ロッドの端にめねじがあるバリエーションをお勧めし
ます)。

 

ケーブルとリード線の領域は十分なスペースが必要です。最小曲げ半径を遵守し、鋭いエッ
ジを避ける必要があります。

3.4 溶接

 

 シリンダーまたは隣接するコンポーネントの溶接作業中は、

 

 溶接電流によるセンサまたはシールへの損傷を避けるために、以下を遵守する必 
 要があります。

 

 - できれば、溶接前にセンサを取り外す必要があります。

 

 - センサが取付けられている場合は、溶接中はすべてのセンサ接続を切断する必要があります。

 

 溶接ユニットの接地接続をシリンダーまたはピストンロッドに接続しないでください。

4 EMC、機械のアースとケーブルのシールド

 

4.1 シリンダーに取り付けられた移動式油圧 EMC 測定は基準シリンダーで実施されました。

 

   ただし、異なるシリンダーを使用すると、EMC 特性が逸脱する可能性がありま 
  す。したがって、重要なアプリケーションでは、システム全体を独自の EMC 
  テストに提出することをお勧めします。

 

正しく動作し、電位差を補正するには、シリンダーを機械のアースに接続する必要
があります。 これは通常、シリンダーと機械の他の部分との機械的接触によって
与えられます。

 

シリンダーが機械に絶縁的に接続されている場合は、個別の接地を確保する必要が
あります。 

内蔵トランスデューサは、金属製の油圧シリンダーによって十分にシールドされて
います。したがって、トランスデューサは、コネクタまたはケーブルコンセントを
介して個別のシールドをする必要はありません。

 

CAN インターフェース:トランスデューサーとコントローラーの間にシールドケー
ブルを使用する場合は、ケーブルシールドを GND に接続する必要があります。

信号

供給 Ub/

供給

CAN インターフェース用のオプション:

GND に接続されたシールド

M12 プラグシステムなどへの金属接続を介した電気接続

 

GND に接続されたシリンダー

Summary of Contents for TM1 Series

Page 1: ...manual mode transducers are subject to modification or manufacturing tolerances 2 6 Check functionality The functionality of the transducer system and all its associated components should be regularly checked and recorded 2 7 Failure malfunction If the transducer system doesn t operate properly it should be taken out of service and protected against unauthorized use 2 8 Limitations for application...

Page 2: ...non magnetic spring washer and circlip For the mounting of the position marker non magnetic material e g stainless steel brass aluminum plastic should preferably be used Mount a non magnetizable spacer of min 5 mm thickness between position marker and cylinder s piston bottom if necessary 3 1 ピストンロッドのボア径 ピストンロッドのボアは 圧力と移動速度に応じて設計します 推奨ボア径 Dk 12 7mm ロッドの端は摩耗から保護する必要があります ポジションマーカーはロッドを引きずってはいけません セ...

Page 3: ... machine ground This is usually given by the mechanical contact of the cylinder with the other parts of the machine If the cylinder is insulately connected to the machine a separate grounding must be ensured e g by a grounding strap The built in transducer is shielded sufficiently by the metallic hydraulic cylinder Therefore the transducer does not provide a separate shielding via the connector or...

Page 4: ...れました ただし 異なるシリンダーを使用すると 測定された EMC 値は大幅に 異なる可能性があります したがって重要なアプリケーションでは システム全体を独自の EMC テストにかける必要があります トランスデューサとコントローラーは シールドケーブルを使用して接 続する必要があります ケーブルシールドは保護アースに接続する必要があります シールド 銅フィラメント編組 85 の被覆率 ケーブル長 30 m 信号 供給 Ub 保護アースに接続されたシールド シールドケーブル シリンダーは 保護アースに接続するか 絶縁するかのいずれかに取り付けることができます 供給電圧 4 3 Application outside of a cylinder with CE conformity accord to EN 61000 6 2 3 Model TM1 _ _ _ _ _ _ _ _ _ _ ...

Page 5: ... in flange TM1 _ _ _ _ 305 _ _ _ _ _ _ フランジが Ø48mm のトランスデューサは フィッティングボア Ø48H8 で 取付けてください フランジとシリンダー間のシールは O リングとサポートリング 付属品 で 実現されています トランスデューサのフランジは M5 セットネジで固定します ケーブル接続 ポジションマーカー Z TH1 P25 のみ 電気的ゼロ点 29 25 mm めねじ付きオプション M4 6 深さ アクセサリー Accessories ポジションマーカーデータシート 例 Z TH1 P18 測定範囲 ケーブル 電気的ゼロ点 配置例 概略図 最小曲げ半径 NT 標準ケーブル 可動アセンブリの場合 50mm 固定アセンブリの場合 25mm 推奨 O リングシール 42 2 3 サポートリング付き 面取り 2 5 15 シリンダー ピスト...

Page 6: ...プレートをシリンダーに取り付けます 次に コンタクトキャリアをフランジプレートにスナップします シリンダー ピストン付きピストンロッド O リングシール 42 2 3 サポートリング付き 面取り 2 5 15 詳細 X および Y は 4 ページを参照 最小曲げ半径 NT 標準リード線 可動アセンブリの場合 14mm 固定アセンブリの場合 7mm 嵌合コネクタ 最大ねじ込みトルク 0 5 Nm 嵌合コネクタ 最大締め付けトルク 0 5 Nm プラグ M12 1 推奨 面取り 1 5 15 プラグ付きモデルは シリンダーの内外への設置に適しています EMC 接地 ケーブルシールドは第 4 章を参照 H8 ...

Page 7: ... ring seals the pressure area of the cylinder at the screw plug hole The contact surface of the flange must seat completely on the mounting surface of the cylinder めねじ付きオプション M4 6 深さ アクセサリー Accessories ポジションマーカーデータシート 例 Z TH1 P18 測定範囲 ケーブル 電気的ゼロ点 O リングシール 配置例 概略図 最小曲げ半径 NT 標準ケーブル 可動アセンブリの場合 50mm 固定アセンブリの場合 25mm シリンダー ピストン付きピストンロッド 電気的ゼロ点 O リング シール 詳細 X 磁化不可能な素材 詳細 X 磁化可能な材料 詳細 Y ISO 6149 に準拠したねじポー...

Page 8: ...gnal output ピン 3 PIN 3 BU 青 blue WH 白 white GND ピン 4 PIN 4 BK 黒 black 接続なし do not connect 4 プラグ M12x1 嵌合コネクタ 最大ねじ込みトルク 0 5 Nm プラグ付きモデルは シリンダーの内外への設置に適しています EMC 接地 ケーブルシールドは第 4 章を参照 注文コード 供給電圧 消費電力 負荷 エラー状態 電気測定範囲 L 外 1W 負荷なし 引き下げる 注文コードの例 インターフェースと接続の割り当て アナログ出力 注文コードの例 電流 電圧 電気接続 電気接続 注文コード 供給電圧 消費電力 負担 エラー状態 電気測定範囲 L 外 エラー状態 ケーブルブレーク GND 1W 負荷なし カスタマイズされたケーブルは異なる色分けを示す場合があります 接続しない というラベルの付いた接続は...

Page 9: ...参照してください ダウンロード 操作マニュアル TM1 をクリックします 6 2 1 CANopen Interface The description of CANopen interface CANopen_Detail and the electronic data sheet EDS can be downloaded from Novotechnik website see Downloads Operating manuals Click on TM1 6 2 2 CAN SAE J1939 Interface The description of CAN SAE J1939 interface CAN_SAEJ1939_Detail can be downloaded from Novotechnik website see Downloads Operating manua...

Reviews: