7  Brief description of the press device (Fig.1) 

The ACO403 press device comprises the press device (8) and a fixed adaptor jaw (9). The head with 

the adaptor jaw can be rotated through 180°. It is only possible to adjust the head before the pressing 

operation. The head cannot be rotated while the pressing operation is being performed.  

To carry out the pressing operation, hold the device tightly on handle (6) and on grip (7) on the 

adaptor jaw. 

7.1  Automatic press cycle (Fig. 1) 

The device features an automatic press cycle. This ensures that the pressing operation is completed 

every time. For safety reasons, the automatic press cycle only switches on when the pressing 

operation has started, i.e. from when the fitting starts to be shaped.  
After the automatic press cycle has been triggered, the green LED (2) goes out and the pressing 

operation runs automatically. The pressing operation can then only be stopped by pressing and 

holding release button (5). After the pressing operation has been completed, the motor automatically 

switches off and the green LED (2) lights up again. 
If start button (1) is released before the automatic press cycle begins, the piston in the press device 

moves back to its starting position. The pressing operation will not have been completed. The pressing 

operation must be triggered again. 

Pos: 27 /RVT/Kurzbeschr eibung/Entlastungsknopf/AC O401 @ 0\mod_1414147298425_18.docx @ 4850 @ 2 @ 1 

 

7.2  Release button 

In the event of an emergency, the pressing operation can be stopped at any time by pressing and 

holding release button (5). The piston in the press device then returns to its starting position.  

Pos: 28 /RVT/Kurzbeschr eibung/F unkschni ttstelle/Funkschnittstell e  -   allgemei n @ 4\mod_1506333322314_18.docx @ 32166  @ 2 @ 1 

 

7.3  Wireless interface (Fig. 1) 

The ACO403 device features a wireless interface with the following characteristics: 

Blue LED (10)

Wireless icon (13)

This wireless interface together with the NovoCheck app can be used to connect the ACO203 to a 

mobile terminal, such as a smartphone, tablet, etc. (Android, IOS; further information at 

www.novopress.de). The following functions are available: 

Readout of the press device

Checking the press device

Making settings

Generating construction site reports.

To establish a connection, the press device must be operational and the NovoCheck app installed on 

the terminal device. 
The press device can now be connected with the NovoCheck app. (For more information, go to 

www.novopress.de)  When the connection was established successfully, the blue LED lights up. 
The blue LED goes out if no connection has been established until the first pressing operation is 

performed. A new attempt to establish the connection can only be made if the press device has been 

switched off in the meantime. It may be necessary to pull the rechargeable battery for this.  
If you do not wish to establish a connection, press the start button once again and perform the 

pressing operation.  

Pos: 29 /RVT/Kurzbeschr eibung/Akku allgemei n/Ü berschrift/AC O102, ACO152, ACO202XL, AXI/AAP102, @ 0\mod_1382447195475_18.docx @ 1453 @ 2 @ 1 

 

7.4  Battery 

Pos: 30 /RVT/Kurzbeschr eibung/Akku allgemei n/Akku ab aufsetzen/ACO102, ACO152, AC O/ECO202, AC O202XL, AF P/EFP202 @ 0\mod_1382442983216_18.docx  @  1433 @  @ 1 

 

Removing the battery (Fig. 2) 

Push in (1) the two release buttons (A) and then remove the battery (2). 

Inserting the battery (Fig. 3) 

Slide the battery into the device as illustrated until it clicks into place. 

Pos: 31 /RVT/Kurzbeschr eibung/Akku allgemei n/Akku Z ustandsanzeig e/AC O401 @ 0\mod_1414147443455_18.docx  @ 4860 @   @ 1 

 

Summary of Contents for ACO403

Page 1: ...Pos 3 R VT Allgemei nes Titelsei ten Kopi e von Titelseite 1 Produkt 0 mod_1401889665157_0 docx 2636 1 ACO403 Pos 4 R VT Allgemei nes L nder kennzeichen L nder kennzeichen D E bis C S 0 mod_1380201864...

Page 2: ...ACO403 7 9 6 3 10 2 5 8 13 1 Pos 6 R VT Strichbil der ACO403 Strichbil d 17cm 4 mod_1511954192677_0 docx 33156 1 1 2 3 4 A B 1 1 2 5 6 7 C D M A B...

Page 3: ...ACO403 8 9 10 15 16 22 24 21 11 12 13 G D K C 14 15 Ende der Liste f r Textmar ke Gr afi k 2 1 1...

Page 4: ...which the relevant press collars have been designed Pos 11 RVT Sicherheit Besti mmungsgem e Ver wendung AC O ECO Besti mmungsgem e Ver wendung Teil 2 neutral 0 mod_1380275436435_18 docx 1037 1 Any use...

Page 5: ...specified service work and service intervals is mandatory Check the press tools and press devices for cracks and other signs of wear before each use Separate all press tools and press devices with mat...

Page 6: ...es when the next service is due Warning ejected fragments Pos 17 RVT Beschrei bung Typenschil d Typenschild AC O403 4 mod_1512556049288_18 docx 33365 1 Information on the rating plate 1 Manufacturer l...

Page 7: ...Measurement uncertainty 1 5 m s Pos 22 RVT Technische Daten Geh rschutz Geh rschutz 2 mod_1469775048472_18 docx 22083 1 Information Wear hearing protection Pos 23 RVT Technische Daten Schwingung allg...

Page 8: ...n Pos 28 RVT Kurzbeschr eibung Funkschni ttstelle Funkschnittstell e allgemei n 4 mod_1506333322314_18 docx 32166 2 1 7 3 Wireless interface Fig 1 The ACO403 device features a wireless interface with...

Page 9: ...es If the green LED 2 flashes following a pressing operation the pressing operation was carried out correctly The battery must be recharged prior to the next pressing operation Pos 34 RVT Kurzbeschr e...

Page 10: ...RVT Inbetri ebnahme und Betrieb Bedeutung der LED Anzeige R ote_LED _leuchtet 0 mod_1400062249067_18 docx 2358 1 Red LED 3 lights up Device fault Press the start button 1 If this is unsuccessful the...

Page 11: ...collar the following 2 steps must be carried out Fig 8 o Press lever 15 at the position marked in the direction of the pipe and hold it there o Grip shell 16 at the position marked from below and swi...

Page 12: ...closed Fig 4a Fingers may get crushed Therefore Leave the adaptor jaw open Fig 4b Pos 51 RVT Inbetri ebnahme und Betrieb Ausg angsl age Press Schlinge 02 Info Gl eitsegmente AC O401 3 mod_149078877482...

Page 13: ...ssschling e ACO EC O202 ACO202XL EC O301 AFP EFP202 0 mod_1386668854154_18 docx 1706 1 Information Ensure there is no gap between the segments of the press collar when the pressing operation is comple...

Page 14: ...before performing cleaning servicing or repair work Pos 59 RVT R einigung Wartung R eparatur 02 Ser viceanschrift AC O102 AC O152 ACO EC O202 ACO202XL EC O301 AC O401 AFP EFP202 AXI AAP102 0 mod_13910...

Page 15: ...y authorised specialist companies Alternatively waste devices can be returned directly to Novopress or a specialist workshop for proper disposal Pos 67 RVT Gew hrl eistung und Gar antie 01a berschrift...

Page 16: ...authorised Novopress workshop Pos 70 RVT Gew hrl eistung und Gar antie 04 Gew hrleistung auf R epar aturen 0 mod_1393238067679_18 docx 1916 1 Repair warranty Novopress provides the following repair an...

Page 17: ...Scharnhorststr 1 Postfach 101163 41460 Neuss 41411 Neuss Germany Germany Tel 49 2131 2880 Fax 49 2131 28855 www novopress de E mail info novopress de...

Reviews: