background image

 

 

Version: 0.1 

Date: 28.04.2009 

Page: 1 / 2 

 

040_NF_DOCU_ADJUSTMENT_Hydraulic_L300_0001_EN_01 

 

 

Hydraulic NovoDock L300 

 

Adjusting instruction 

 

Article no. hydraulic unit:   

DS0110100 

Motor power:  

 

 

0,75kW 

Design: 

 

 

 

Swing lip with 1 solenoid valve 

 
Basic requirement: 

The electric and hydraulic components of the dock 
leveller are completely installed. A pressure gauge is 
connected to the measuring port „M“. 

 

Adjusting the lift pressure 

  Press "Lift" button. If there is not enough pressure to lift the platform, unlock the spindle of 

valve DB and turn clockwise until the platform rises. 

  Swing out the lip automatically. If the swing does not swing out, unlock spindle of 

valve V2 and turn anticlockwise until the lip swing out. 

  Keep the "Lift" button pressed. Adjust the valve DB to 140 bar, measured at 

measuring point „M“, by turning the spindle (clockwise rotation = pressure higher, 
anticlockwise rotation = pressure lower). 

  Lock the spindle by tightening the lock nut. 

  Check the tightness of the valves. Raise the leveller platform to its uppermost position 

and switch off the mains isolator. If the platform does not sink, all valves are tight. 

 

Adjusting the automatic swing out movement 

  Press "Lift" button and raise the platform completely. 

  Check if the lip swings out automatically. If the lip does not swing out unlock spindle 

of valve V2 and turn anticlockwise until the lip swing out (switch pressure 120 bar). 

  Let the platform sink to its lowest position. The lip must remain swung out while the 

platform sinks. If the lip swings back turn the spindle more anticlockwise. 

  Raise the leveller platform by pushing the “Lift” button. The lip must not swing out 

while the platform rises. If the lip swings out turn the spindle of valve V2 clockwise 
until the lip does not swing out while the platform rises. 

  Lock the spindle by tightening the lock nut. 

 
Remark:

 The swing out/ in speed of the lip is not adjustable. 

 

Adjusting the sink speed 

  Unlock and turn the spindle of valve DV1 clockwise to its stop (close). 

  Press "Lift" button and raise the platform completely. 

  Turn the spindle anticlockwise so that the sink speed between uppermost and 

horizontal position of the platform is 150mm/s, measured at the front edge of the 
platform. 

  Lock the spindle by tightening the lock nut. 