Setting up 64-xx / AP 5.x
Setup the printer for rewinder-use by performing the following steps:
Selecting the direction of rotation
on page 13.
on page 15.
How to perform the steps is explained in the following.
A complete description of the parameters can be found in the topic section
"Info Printouts and Parameters" in the user manual of the printer.
Activating the rewinder
CAUTION! - Selecting a non-existent option can cause the device to
malfunction!
Set
SYSTEM PARAMETERS > Periph. device
to “Rewinder”.
Don´t select “Intern Rewinder” by mistake, which activates the internal
rewinder of the printer.
Afterwards, the rewinder restarts and in menu
PRINT PARAMETER
appears
additionally the parameter
Rewind direction
for setting the rewind direction.
Selecting the direction of rotation
Action
Display
1. Call
PRINT PARAMETER > Rewind direction.
Rewind direction
2. Press the Online button.
Rewind direction
Printing inside
3. (For „Printing outside“ only) Press the Cut button. Rewind direction
Printing outside
4. Press the Online button
Rewind direction
5. Repeatedly press the Prog button until
OFFLINE 0 JOBS
Checking the sensor current setting
Call
SERVICE FUNCTION > Rewinder values
.
Rewinder Values
xxx <--------------------> yyy
•
xxx = Sensor value in zero position
•
yyy = Sensor value in final position (Dancer arm at the printer side limit)
The difference yyy – xxx must
at least
be 80 (best: 100). If the difference is
less, the sensor current setting must be changed, see chapter Setting the
sensor current below.