![Novexx Rewinder 2000 Service Manual Download Page 26](http://html1.mh-extra.com/html/novexx/rewinder-2000/rewinder-2000_service-manual_1712056026.webp)
02/17 Rev. 02
SERVICE MANUAL
Attachment, Setup, Service
Rewinder
2000
8
Setting the sensor current
Befor using the rewinder for the first time, the sensor current must be set by
a potentiometer at the rewinder [1].
[1] The pot. can be accessed through a slot in the back cover of the rewinder.
Action
Display Note
1. Select
parameter
OTHR > SCHK
.
SCHK
2. Press the ENTER button
Pxxx
Other information may be
displayed depending on the
printer type; xxx = variable
value.
3. Repeatedly press the CUT button
until
Wxxx
4. Set the rewinder pot. [1] so that a
value between 20 and 30 is
displayed.
W20
Dancer arm in zero position [2];
24 = set value.
5. Move the dancer arm to the final
position (towards the support
leg). Check the displayed value*.
W141
141 = set value (example) in the
final position; Value difference =
117 (o.k.)
*) The value with the dancer arm in its final position must be at least 100 higher than the value
in zero position, which was set in step 4. Most important ist the difference between the two
values in the two end positions: the difference must equal/be higher than 100, ideally 110.
Repeat step 4 and set a higher value in the zero position, if the difference is too little.
Pot. (P101)
Z0139E.cdr
Turn counter-clockwise =>
Sensor current decreases
Displayed value increases
Turn clockwise =>
Sensor current increases
Displayed value decreases
Rewinder (section)