Installation
7. Attach the label in the centered below the M12 plug
8. Replace the fuse on the AI board by the fuse (T4A)
that came with the kit.
9. Reassemble the rear cover.
10. Check the machine according to the local regula-
tions about repair, modification and inspection of
electrical equipment.
Connection to the power supply
Pin assignment of the built-in connector [17]:
Matching parts either for manual cable preparation or
fully sealed are available from different manufacturers.
Power supply
Appropriate safety standards for the power supply itself
and its installation must be observed. Only tested and
certified power supplies are allowed, e.g.:
• Siemens SITOP series
• Wago EPSITRON series
• Weidmüller Connect Power series
• Kosel KH series
Pin
Assignment
Wire color at cable
1
24 V DC / max. 4A
brown
2
not connected
3
24 V GND
blue
4
not connected
[15] Position of the label.
[16] Fuse (A) on the AI board (RH machine).
[17] Pin assignment on the connector side.
AI SUPPLY
24VDC / max. 4A
A
A
Summary of Contents for ALX 92x
Page 3: ...Release 3 6 2016 SERVICE MANUAL ALX 92x Print Apply system ...
Page 356: ...12 14 Rev 05 SERVICE MANUAL Service Electronics 64 xx Gen 2 DPM Gen 2 ALX 92x Gen 2 43 ...
Page 508: ...Edition 1 3 2016 INSTALLATION MANUAL AI retrofitting kit for ALX 92x ...
Page 509: ......
Page 511: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 4 Content ...
Page 520: ...Installation Manual AI retrofitting kit for ALX 92x 03 2016 00 13 Installation ...
Page 521: ......
Page 522: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...