SIGNAL INTERFACE
General notes
The signal interface is in series a D-Sub15 (fem.) connector [?A]. The machine can additionally
(optionally) be equipped with separate M12 sockets for inputs and outputs [142][143].
The signal interface can be used as interface for applicator signals or for PLC signals. The selection
of the interface type is done via the function menu:
– PLC signals:
SIGNAL INTERFACE > Interface mode
= „PLC signals“.
– Applicator signals:
SIGNAL INTERFACE > Interface mode
= „Applic. signals“.
Recommended connector:
– Novexx article no.: A8144 (male), A8145 (fem.)
–
Manufacturer
: Franz Binder GmbH
–
Order no.
: 713 1 99 1487 812 08
See
www.binder-connector.de
[141] Position of the signal interface (A) at a RH machine with „Gen. 2“-Electronics.
[142] Position of the M12 sockets.
A