![Novell ZENWORKS LINUX MANAGEMENT 7.2 IR2 - 07-20-2009 Installation Manual Download Page 101](http://html.mh-extra.com/html/novell/zenworks-linux-management-7-2-ir2-07-20-2009/zenworks-linux-management-7-2-ir2-07-20-2009_installation-manual_1711962101.webp)
Upgrading to ZENworks 7.2 Linux Management with IR1/IR1a
101
no
vd
ocx
(e
n)
13
Ma
y 20
09
The Remote Execute policy is enforced as scheduled, after the managed devices’ next
scheduled refresh. If the time you specified in
Step 11
occurs before the next scheduled refresh,
the policy is enforced on the next refresh.
IMPORTANT:
It takes approximately five minutes for the upgrade bundle to be installed and
for the upgrade process to be performed. Do not perform any rug commands such as
rug ref
during the upgrade process. Executing rug commands during the upgrade process might cause
the process to fail.
After the upgrade completes, you can verify that the upgrade was successful by executing the
rug ping
command or refer to
upgrade.log
. The upgrade was successful if the version of
zmd is 7.2.0. If you perform the
rug ping
command prematurely, you receive an exception
message. You can recover by stopping and restarting zmd. The
/tmp/zmd/upgrade.log
must
contain the
“Starting ZENworks Management Daemon...”
message in the last line.
NOTE:
Bundle and Package history is not migrated.
Upgrading SLES 10 or SLED 10 Managed Devices by Using an Upgrade Bundle
Perform the following steps on the SLES 10 or SLED 10 managed device:
1
Execute the
/usr/bin/rug sub
catalog_name
command, where
catalog_name
is the
catalog assigned to the managed device.
2
Execute the
/usr/bin/rug bin -y
upgrade_bundle_name
command, where
upgrade_bundle_name
is the upgrade bundle in the catalog assigned to the managed device.
IMPORTANT:
It takes approximately five minutes for the upgrade bundle to be installed and
for the upgrade process to be performed. Do not perform any rug commands such as
rug ref
during the upgrade process. Executing rug commands during the upgrade process might cause
the process to fail.
After the upgrade completes, you can verify that the upgrade was successful by executing the
rug ping
command or refer to upgrade.log. The upgrade was successful if the version of zmd
is 7.2.0. If you perform the
rug ping
command prematurely, you receive an exception
message. You can recover by stopping and restarting zmd. The
/tmp/zmd/upgrade.log
must
contain the
“Starting ZENworks Management Daemon...”
message in the last line.
3
If the device does not have the X Window System installed:
3a
In ZENworks Control Center, click the upgrade bundle.
3b
Click the
Details
tab.
3c
In the
Packages
panel, select the following packages:
novell-zenworks-x11vnc-0.6.1-2
novell-zenworks-zmd-gconfpolicyenforcers-7.2.1-0
novell-zenworks-tightvnc-1.2.9-6, zen-updater-7.2.1-0.1
3d
Click
Action
>
Set Freshen
.
Summary of Contents for ZENWORKS LINUX MANAGEMENT 7.2 IR2 - 07-20-2009
Page 4: ...4 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 10: ...10 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 12: ...12 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 14: ...14 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 22: ...22 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 24: ...24 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 32: ...32 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 38: ...38 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 46: ...46 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 62: ...62 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 64: ...64 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 66: ...66 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 72: ...72 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 92: ...92 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 114: ...114 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 116: ...116 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...
Page 122: ...122 Novell ZENworks 7 2 Linux Management Installation Guide novdocx en 13 May 2009 ...