6.1.3 Comparison of RAID Performance
The following table compares the read and write performance for RAID devices.
Table 6-3
Read and Write Performance for RAIDs
6.1.4 Comparison of Disk Fault Tolerance
The following table compares the disk fault tolerance for RAID devices.
Table 6-4
Fault Tolerance for RAIDs
5
Stripes data and records
parity to a dedicated disk. If
disks are different sizes, the
smaller disk determines the
size of the RAID.
Improves disk I/O performance for both reads and writes.
Write performance is considerably slower than for RAID 0,
because parity must be calculated and written. Write
performance is slightly slower than RAID 5. Read
performance is slower than for a RAID 1 array with the same
number of component devices.
This type of striping is seldom used because if the parity disk
is lost, the parity data cannot be reconstructed. The parity
disk can become a bottleneck for I/O.
Raid Level
Read Performance
Write Performance
0
Faster than for a single disk
Faster than for a single disk and other
RAIDs.
1
Faster than for a single disk, increasing as
more mirrors are added
Slower than for a single disk, declining as
more mirrors are added.
4
Faster than for a single disk; comparable to a
RAID 0
Faster than a single disk. Slower than a
RAID 0 because of writes for parity.
5
Faster than for a single disk. Slower than a
RAID 0 because one disk is used for parity
Faster than for a single disk. Slower than a
RAID 0 because of writes for parity. Slower
than a RAID 4 because of possible
bottlenecks for writes of parity to the same
disk.
Raid Level
Number of Disk Failures Tolerated
Data Redundancy
0
None
No
1
Number of disks minus 1
100% redundancy for each mirror
4
1
Distributed parity to reconstruct data
5
1, but not the parity disk
Dedicated parity disk to reconstruct data
RAID Level Description
Performance and Fault Tolerance
Summary of Contents for LINUX ENTERPRISE SERVER 10 - STORAGE ADMINISTRATION GUIDE FOR EVMS
Page 4: ...novdocx ENU 9 January 2007 ...
Page 8: ...8 SLES 10 Storage Administration Guide for EVMS novdocx ENU 9 January 2007 ...
Page 10: ...10 SLES 10 Storage Administration Guide for EVMS novdocx ENU 9 January 2007 ...
Page 40: ...40 SLES 10 Storage Administration Guide for EVMS novdocx ENU 9 January 2007 ...
Page 52: ...52 SLES 10 Storage Administration Guide for EVMS novdocx ENU 9 January 2007 ...
Page 74: ...74 SLES 10 Storage Administration Guide for EVMS novdocx ENU 9 January 2007 ...
Page 84: ...84 SLES 10 Storage Administration Guide for EVMS novdocx ENU 9 January 2007 ...