1.
Application
The XSZ-107 series microscope is a multi-purpose bio-microscope that has been specifically designed for
clinical and chemical examination. The application and use of this series of microscopes is very diverse and
extends to professional research, teaching demonstration, use in medical and health establishments,
laboratories, technology, research and tertiary education facility. Its accessories make the instrument
capable of accomplishing a very diverse and wide range of practical use. The XSZ-107 can be adapted in
many ways including phase contrast, florescence, photography, camera depiction, television and computer
based image processing. The XSZ-107 can also be used for routine work in the fields of biology,
bacteriology, histology, cytology, haematology and pharmacology easily (to name a few).
The microscope unit is used in conjunction with the epi-fluorescent attachment which has been designed
for use with and including our biological microscopes such as the Novel N-400M, Novel N320M and the
Novel XSZ-107CCD.
2.
Safety Note
a.
Carefully open the box, avoid the accessories dropping to the ground and being damaged.
The epi-fluorescent attachment is a precision instrument.
b.
Please ensure that the entire unit is kept out of direct sunlight, high temperatures, humid or
dusty environments.
c.
Make certain that the power cords are installed correctly and that all other components are
connected firmly.
d.
Do not open any of the lamp housings while they are turned on or for at least 10 minutes
after they have been turned off. These parts are extremely hot and can cause burns if
touched.
e.
Always be sure to ground (earth) the equipment.
f.
Verify that the voltage and the frequency of the AC mains outlet match the setting of the
voltage switch and the frequency switch on the rear of the power supply units.
g.
Always use the power cord provided by NOVEL and make sure that the main switch is
moved to “O” (OFF) before connecting the power cord plug to the wall outlet.
h.
To prevent any hazard, always turn the main switch on the power supply unit to “O” (OFF),
unplug the power cord plug from the mains outlet before replacing any bulb or the fuse, and
wait for at least 10 minutes before replacing the bulb.
i.
To prevent obstruction of the air flow, it is important to make sure to leave enough space
around and above the lamp housing of the microscope as well as epi-florescence
attachment.