SMART6 User Manual Rev 3
69
Factory Defaults (Bluetooth model):
serialconfig com1 9600 n 8 1 n on
serialconfig com2 9600 n 8 1 n on
serialconfig aux 115200 n 8 1 n off
ASCII Example:
serialconfig com1 9600 n 8 1 n off
Field
Field Type
ASCII
Value
Binary
Value
Description
Format
Binary
Bytes
Binary
Offset
1
SERIALCONFIG
Header
-
-
This field contains the command
name or the message header
depending on whether the
command is abbreviated ASCII,
ASCII or binary.
-
H
0
2
port
COM1
Select COM port 1 to configure
Enum
4
H
COM2
2
Select COM port 2 to configure
AUX
3
Select COM port AUX to configure
THISPORT
6
Select the current COM port
(default)
ALL
8
Select all COM ports
3
bps/baud
a
300, 600, 900, 1200,
2400, 4800, 9600,
19200, 38400, 57600,
115200, 230400,
460800 and 921600
Communication baud rate (bps).
Ulong
4
H+4
4
parity
N
0
No parity (default)
Enum
4
H+8
E
1
Even parity
O
2
Odd parity
5
databits
7 or 8
Number of data bits
(default = 8)
Ulong
4
H+12
6
stopbits
1 or 2
Number of stop bits
(default = 1)
Ulong
4
H+16
7
handshake
b
N
0
No handshaking (default)
Enum
4
H+20
XON
1
XON/XOFF software handshaking
8
break
c
OFF
0
Disable break detection
Enum
4
H+24
ON
1
Enable break detection (default)
AUTO
2
DEFAULT
3
a. On models without Bluetooth, the AUX port does not support 230400, 460800 or 921600.