Troubleshooting
7.1
Examining the RXSTATUS Log
The RXSTATUS log provides detailed status information about your receiver and can be used to
diagnose problems. Refer to the
OEM6 Family Firmware Reference Manual
(OM-20000129) for details
on this log and on how to read the receiver error word and status word.
Table 10, Resolving a Receiver
page 86 and Table 11, Resolving an Error in the Receiver Status Word
page 87 on
have actions to take when your receiver has an error flag in either of these words. If you
are not able to resolve the condition, contact
Table 10: Resolving a Receiver Error Word
Overload and overrun problems.
Either the CPU or port buffers are
overloaded
Reduce the amount of logging or increase the baud rate. See also
3, OEM6 Card Default Serial Port Configurations
The receiver is indicating that an
invalid authorization code has been
used
Refer to the VERSON or VALIDMODELS logs and the
MODEL
or
AUTH
commands in
the
OEM6 Family Firmware Reference Manual
(OM-20000129)
The receiver is being affected by
jamming
Move the receiver away from any possible jamming sources
The receiver’s Automatic Gain
Control (AGC) is not working
properly
Section 2.3.1, Choosing a Coaxial Cable, page 23
and the jamming
symptom in this table
Bit Set
Action to Resolve
0-2
Issue a
FRESET
command (for bit 1, reload new firmware)
4
Contact
5
Check the VERSION log. The VERSION log will indicate "Invalid authcode". Upgrade the auth-code
as described in
8.5Upgrading Using the AUTH Command on Page 99
6
Issue a
FRESET
command
7
See
Section 2.4, Power Supply Requirements, page 24
8
Reserved
9
Check temperature ranges in the ENVIRONMENTAL table sections of all Appendices specific to the
product
10-12
Possible hardware or environmental condition. If you cannot resolve the problem, contact
13-14
Reserved
15
Issue a
FRESET
command and power cycle the unit. If the bit is still present, contact Customer
Support
16
Monitor CPU idle time. Reduce number of logs or the rate of data logging
17
Ensure that the version log is consistent with the hardware
20
SoftLoad is in progress. See
Section 8.4, Updating Using SoftLoad Commands, page 93
21
You may be exceeding the receiver’s velocity limit. If so, reduce velocity. This error can only be
cleared by resetting the receiver
22
Reload firmware using WinLoad or the SoftLoad commands
31
Possible hardware failure. Contact