Novatech Pulsafeeder MicroVision Timer Installation & Operation Manual Download Page 28

72-910-23 Rev.F 
Page 28 of 30 

16.  MOUNTING HOLE PATTERN (Footprint) 

 

Fig. 7 

(866) 433-6682 • (281) 359-8538 • [email protected] • www.novatech-usa.com

Summary of Contents for Pulsafeeder MicroVision Timer

Page 1: ...Rev F Page 1 of 30 MicroVision Timer MICROPROCESSOR TIMER CONTROLLER Installation Operation Manual sales novatech usa com www novatech usa com Tel 866 433 6682 Fax 866 433 6684 Tel 281 359 8538 Fax 28...

Page 2: ...Input 5 12 5 5 Alarm Relay 12 6 FRONT PANEL DESCRIPTION 13 6 1 Keypad Operation 13 7 CONTROLLER PROGRAMMING 14 7 1 Menu Tree 14 7 2 Menu Navigation 14 7 3 Home screen 15 7 4 Main Menu 15 7 5 Status S...

Page 3: ...rt Times 24 12 Factory Defaults 25 13 TROUBLESHOOTING GUIDE 26 14 MAINTENANCE 27 15 SPECIFICATIONS 27 16 MOUNTING HOLE PATTERN Footprint 28 17 Factory Service Policy 29 18 Warranty 29 866 433 6682 281...

Page 4: ...follows Relay 1 Timer 1 Relay 2 Timer 2 Relay 3 Timer 3 Relay 4 Timer 4 Relay 5 Alarm or Timer 5 normally open dry contact 2 MICROVISION FEATURES 2 1 Output Relays The control of the four HANDS OFF AU...

Page 5: ...put is active closed Open no flow closed flow If a flow switch input or other alarm condition exists the four 4 LED s will flash until the alarm condition is cleared 2 5 Water Meter Each input may be...

Page 6: ...nal state and local codes AVOID LOCATIONS WHERE THE CONTROLLER WOULD BE SUBJECTED TO EXTREME COLD OR HEAT LESS THAN 0 F 17 8 C OR GREATER THAN 122 F 50 C DIRECT SUNLIGHT VIBRATION VAPORS LIQUID SPILLS...

Page 7: ...ound on the page 22 of manual 3 4 Flow Sensor Switch If your controller is provided with a flow switch install the flow switch so that flow enters into the bottom of the flow switch tee and out of the...

Page 8: ...tion that could cause damage to both the equipment and the personnel operating it Pay close attention to any warning Primary Supply Ground must be connected to earth ground for safe operation of your...

Page 9: ...s The controller should be connected to a dedicated power branch i e its own wiring circuit breaker etc For best results the ground should be independent true earth not shared A switch or circuit brea...

Page 10: ...on the relay board Fig 4 The top part of this terminal block is removable to allow for easy access to the connector s three 3 screws Devices attached to any Relay connection must be Single Phase and r...

Page 11: ...t be run separate from AC power lines J10 J4 J5 TIMER 5 RELAY N O J3 J2 5V DRUM LEVEL DETECTORS CONTACT METER 5V GND J3 5V J3 OR TOP BOARD WATER METER TYPES GND INPUT 1 TIMER 5 FLOW SWITCH FLOAT 16 17...

Page 12: ...el open level is OK 5 4 3 Input 5 Connect your water meter drum level switch flow switch or auxiliary dry contact wires to J4 If you do not have a flow switch a jumper wire must be connected across J4...

Page 13: ...function keys Used to move the select highlighted box and to increase and decrease values O O Soft keys used for various functions depending on currently displayed screen The key s function appears ab...

Page 14: ...different menus Use these buttons to move up and down within a list of options or move right and left to enter or change parameter values In some cases the Microvision display will prompt you to pres...

Page 15: ...is menu allows you to set the timer feed modes 7 5 Status Screen This screen shows the real time data relating to the controller This screen can be used to log the amount of time a particular output w...

Page 16: ...time and time format HOA Outputs Manually control the five relays Inputs Set the input type drum level or water meter type and volume Gal Lit Set the display in Gallons or liters Scrolling Set the ti...

Page 17: ...ical pumps or troubleshooting electrical problems You must first select the relay output to be controlled then select the relay state Auto Return the control output to normal operation On 5 Min Energi...

Page 18: ...um level indication Your choices are to allow the pump to continue to run or have the pump stop when its drum level goes low Input one is tied to relay one Pump Stops Selecting this mode causes the ti...

Page 19: ...timer s status to the next timer on the home screen Scrolling Set the number of seconds to scroll 7 14 Totalizers From the Totalizers screen you can view the totalized values of each of the five poss...

Page 20: ...s in real time This is a great tool for checking the correct operation of sensors that are attached to the controller Flow input Water flow switch input J4 pins 1 2 Flow closed No flow open Drum Level...

Page 21: ...ry defaults Be absolutely certain you want to reset all the parameters back to the factory defaults Once the reset takes place there is no way to retrieve the previous parameters 11 Settings Menu From...

Page 22: ...ulate a certain volume of water before the inhibitor is feed Once the accumulated volume is reached the inhibitor is feed for the programmed Feed Time Feed Time Set this value to the amount of time yo...

Page 23: ...nd weeks by using the up and down buttons to the right of the display Move the cursor to the right or left by using the button to the bottom of the display The selected day or week will flash as the c...

Page 24: ...s and or weeks is acceptable for each timer Select the timer start days and weeks by using the up and down buttons to the right of the display Move the cursor to the right or left by using the button...

Page 25: ...Format MM DD YY Time Format 12hr Clock Inputs Dry Contact Water Meter Pulse Volume 100 Units Gallons Drum Levels Pumps Run Scrolling 3 Seconds Display Contrast 26 Password 0000 disabled Settings Time...

Page 26: ...ow switch wiring or connector loose Check flow switch connections see Figure 5 Page 8 Flow switch stuck Clean flow switch sensor mechanicals Flow assembly clogged Clean inside flow assembly Flow switc...

Page 27: ...e Lag T F37 1A 2AG Time Lag 250VAC 15 SPECIFICATIONS Controller Enclosure NEMA 4X Designed to meet IP65 Enclosure Dimensions 6 4 x 3 2 x 3 2 163 x 82 x 82mm Power supply 120 or 220 VAC 50 60Hz Display...

Page 28: ...72 910 23 Rev F Page 28 of 30 16 MOUNTING HOLE PATTERN Footprint Fig 7 866 433 6682 281 359 8538 sales novatech usa com www novatech usa com...

Page 29: ...f defects in material or workmanship Liability under this policy extends for 24 months from date of shipment Electrodes probes are considered maintenance items and as such are warranted for six 6 mont...

Page 30: ...Airport Rd Punta Gorda FL 33982 USA 941 575 3800 www pulsa com European Union EU PULSAFEEDER Europe Via Kennedy 12 20090 Segrate Milano Italy sales novatech usa com www novatech usa com Tel 866 433 6...

Reviews: