72-910-23 Rev.F
Page 10 of 30
5.1 RELAY BOARD CONNECTIONS
3
HO
T
RE
T
HO
T
RE
T
AC POWER IN
MOTORIZED BALL VALVE
(4-WIRE)
PUMP
(3-WIRE)
(RETURN / NEUTRAL)
(EARTH / CHASSIS GROUND)
(NORMALLY / OPEN)
(RETURN / NEUTRAL)
(EARTH / CHASSIS GROUND)
(NORMALLY / OPEN)
(NORMALLY / CLOSED)
T 1
T 2
T 3
T 4
SUPPLY
T 1
T 2
T 3
T 4
5A
F2
5A
F1
HOT
RET
HOT
RET
HO
T
RE
T
HO
T
RE
T
HO
T
RE
T
HO
T
RE
T
PL2
PL3
PL4
PL5
HOT
no
nc
Fig. 4
5.2 Conduit Models (Wiring High Voltage)
4
Conduit controllers have openings for conduit connections for hard wiring.
(See Fig.
4)
for input and output power connections. Use only 18 AWG (1,2 mm²) stranded wire
for conduit power and load connections. Supply (input) power is connected via
PL5
located on the relay board
(Fig. 4)
. The top part of this terminal block is removable to
allow for easy access to the connector’s three (3) screws.
Devices attached to any Relay connection must be Single Phase and rated for
the same voltage as the input voltage to the product. (e. g. 120VAC MicroTrac
controllers support 120VAC relay attached devices exclusively and 220VAC
MicroTrac controller support 220VAC relay attached devices exclusively.) Do
not apply power until this condition is verified.
Make sure that all conduit connections are water tight
.
3
Trained service personnel are required for all electrical connections. This product does not contain operator
serviceable parts.
4
Trained service personnel are required for all electrical connections. This product does not contain operator
serviceable parts.