background image

 

 
© NOVATEC, Inc. 2013 All Rights Reserved                                                            

 

VL-VLP IM 4-12-2013 

 

 

                                                 

22 

 

16- VLP SERIES LOADERS PARTS LIST 

 
 
 

04533 

Brush set for #04250 Vacuum Motor 

For VLP-5 

50036 

Carbon Brushes, set of two 

Carbon Brushes, set of two, for motor part #50033 & 01381. 
 VLP-12, -19, -38 

04505 

Deflector Assembly, Articulated, 1.5” 

Deflector assembly for 1.5" line size. 

08989 

Dump Flapper for MM, Aluminum 

Dump Flapper, Aluminum (flapper only) for Machine Mount 
Dump Flapper assembly (#09662) 

01-1664 

Dump Flapper for MM, SS 

Dump Flapper, Stainless Steel (flapper only) for Machine 
Mount Dump Flapper assembly (#09662) 

09662 

Dump Valve assembly for Machine Mount, with Flapper 

Dump Valve assembly with Aluminum Flapper, for Machine 
Mount assemblies. 

02778 

Dump Valve Flapper, 2" Aluminum 

 

08598 

Dump Valve Flapper, 2" SS 

 

02155 

Dump Valve Flapper, Optional SS, for 5” dump valve 

Optional Stainless Steel Flapper for the 5" dump valve used 
on VLP-12, -19, -38 

50210 

Dump Valve Flapper, Standard Aluminum, for 5” dump 
valve 

Standard Aluminum Flapper for the 5" dump valve used on 
VLP-12, -19, -38. 

11644 

Filter Cartridge - 4" O.D. X 10" long  (3) required for 
VLP-12 and VLP-19 (1) required for VLP-5 

 

11645 

Filter Cartridge - 6" O.D. x 20" long (3) required 

For VLP-38 

KIT-S0018 

Filter Cartridge Kit - Includes: (3) of part #11645 Filter 
Cartridge, 6" OD X 3.5" ID x 20"Lg, Polyester W/PTFE 

For VLP-38 

KIT-S0016 

Filter Kit, includes three (3) of part #11644 Filter 
Cartridge 

Kit includes three (3) of part #11644, Filter Cartridge, 4 OD 
X 2.5 ID X 10Lg, Polyester W/PTFE, 1 Micron.  For VLP-12, 
-19 

01695 

Gasket seal, 3", Standard Neoprene Black,  
(200 degree F) 

Standard Neoprene (200 degree) Gasket, 3" (Nominal);  
Used for the Standard Discharge Gasket for the 2" dump 
valve.  

50026 

Gasket seal, 5", Standard Neoprene black,  
(200 degree) 

Standard Neoprene (200 degree) Discharge Gasket for the 
5" dump valve, 6.875" diameter 

50245 

Mercury Tilt Switch 

 

09029 

PLC, LOGO, 230RC, 115-230vac 

 

08758 

Sight Glass, Tube, 3.5" diameter x 8" long 

Tube Borosilicate Glass, 3.5" OD, 8" Long 

09007 

Solid State Relay, 115vac 

 

04250 

Vacuum Motor, 115 volts AC 

For VLP-5

 

50033 

Vacuum Motor.  115 Volts AC 

For VL-12,-19,-38

 

09758 

VL Controller, complete, 115vac 

Replacement VL control box, complete with LOGO mini-
PLC controller, line cable and plug and interconnect cable 
with 8 pin gang plug. 115vac operation 

097581 

VL Controller, complete, 230vac 

Replacement VL control box, complete with LOGO mini-
PLC controller, line cable and plug and interconnect cable 
with 8 pin gang plug. 230vac operation 

asVR-MM-8 

 

asVR-MM-12 

 

asVR-MM-16

 

8 lb. Sight Glass Conversion Kit 

 

12 lb. Sight Glass Conversion Kit 

 

16 lb. Sight Glass Conversion Kit 

Conversion Kit to increase sight glass capacity for  
VL & VLP-12 and -19 models. Includes base, borosilicate 
glass, top adapter plate and discharge valve. 

  

Part #:                            Description                                           Additional Information 

Summary of Contents for VL Series

Page 1: ... 12 VL 19 VL 38 VLP 5 VLP 12 VLP 19 VLP 38 VACUUM LOADERS VL and VLP Series DOCUMENT VL VLP IM 4 12 2013 VL 12 Model Pellet and Regrind Loader VLP 38 Model Powder Loader VL 5 MM Machine Mount Pellet Loader Mini PLC Self Contained Loader Control NOVATEC Inc 2013 All Rights Reserved ...

Page 2: ...spond to any of your requests Instruction Manual VL VLP IM 4 12 2013 Model ___________________________ Serial ____________________________ DISCLAIMER NOVATEC Inc shall not be liable for errors contained in this Instruction Manual nor for misinterpretation of information contained herein NOVATEC shall not in any event be held liable for any special indirect or consequential damages in connection wi...

Page 3: ...METERS 9 8 2 PARAMETERS EXPLANATION 9 9 INITIAL START UP 11 9 1 CONVEYING NOTES 11 10 MAINTENANCE 12 10 1 VL Series FLAT FILTER CLEANING 12 10 2 VLP Series CARTRIDGE FILTER CLEANING 13 10 3 VACUUM MOTOR BRUSH REPLACEMENT 14 10 4 VL 12 through VL 38 and VLP 12 through VLP 38 MOTOR BRUSH REPLACEMENT 15 10 5 VL 5 VLP 5 MOTOR BRUSH REPLACEMENT 15 10 6 MOTOR REPLACEMENT 16 11 TROUBLESHOOTING 17 12 WARR...

Page 4: ...demand The sensor is attached to an adjustable bracket that slides along the length of a clear sight tube serving as a Just in Time JIT material hopper mounted between the machine throat and loader discharge The sensor height on the site tube determines the level of material that triggers a demand for more material and a new load cycle The sensor may be either a capacitance style with sensitivity ...

Page 5: ... immediate operation and include a hardware package The hardware package includes 15 feet of flexible vacuum hose hose clamps and a material pick up lance Options Additional tubing and fittings Rigid tubing elbows bolted couplers etc Alternate sight glass sizes are available for most Machine Mount models 220 1 50 60 Volt Power Brushless Motor for VL 38 Accessories asVR MM 8 asVR MM 12 asVR MM 16 8...

Page 6: ...id tubing elbows bolted couplers etc Alternate sight glass sizes are available for most Machine Mount models 220 1 50 60 Volt Power Brushless motor for VLP 38 Accessories asVR MM 8 asVR MM 12 asVR MM 16 8 lb Sight Glass Conversion Kit 12 lb Sight Glass Conversion Kit 16 lb Sight Glass Conversion Kit Conversion Kit to increase sight glass capacity for VL VLP 12 and 19 models Includes base borosilic...

Page 7: ...installation Use flexible material handling hose to connect the material pick up lance or vacuum take off box to the conveying line The flexible hose should be only as long as needed since excess hose will reduce loader efficiency Connect a clean dry compressed air supply line to the filter on the accumulator tank The minimum requirement for effective filter cleaning is 80 PSI CAUTION 1 DO NOT EXC...

Page 8: ...ger a sensor placing the system in a holding mode As material is consumed by the process and flows from the hopper below the loader the material level will fall the flapper will close or sensor will be uncovered and the loader will begin to load automatically again to keep the hopper full NOTE Once the vacuum motor starts a loading cycle will continue through the load dump and pulse cycles even if...

Page 9: ...r will run to load material into the loader s vacuum chamber Too little time will result in insufficient loading and will shorten motor life with too many start stop cycles Too much time will pack the loader full of material prematurely blinding the filter and possibly clogging the conveying line This setting should be adjusted over the course of several normal loading cycles to just fill but not ...

Page 10: ...ing the course of the Motor On time Time setting A counts down during loading at which time the valve switches to allow the B time setting to take over A and B will repeat until the Motor on time expires Short A and B time settings will allow multiple layers of virgin and regrind materials to be loaded for rough mixing of the two materials during loading However short cycles require each flow of m...

Page 11: ... time so that it is only 1 to 2 seconds longer than the time necessary to completely empty the chamber The number of pulses needed to clean the filter depends upon the material being conveyed Clean virgin pellets require minimum filter cleaning while very dusty regrind or powder may necessitate a maximum filter cleaning sequence Adjust the pulse cycle so the filter s remain clean A mid range setti...

Page 12: ...r is recommended to remove collected resin debris dust and fines If compressed air is used be sure to wear goggles and blow from the top coarse screen side of the filter down through the filter media Never bang the filter against a hard surface to dis lodge debris Distortion of the media or sealing ring can result Once clean thoroughly inspect the filter for severe wear holes tears and material ab...

Page 13: ...he filter plate and cleaned in place However full removal and thorough cleaning of each cartridge is highly recommended Vacuum clean the outside of the filter s to remove collected resin debris dust and fines If compressed air is used be sure to wear goggles and blow from the inside of the filter s down through and out of the filter media Never bang the filter s against a hard surface to dis lodge...

Page 14: ... on the lid must be centered over a cartridge filter for effective blowback action Replace the clamp and tighten With newly installed filter plate seals the clamp may need to be adjusted to provide a vacuum tight and mechanically firm seal 11 3 VACUUM MOTOR BRUSH REPLACEMENT Brushes should be examined for wear and changed before the brush holder or non brush components touch the commutator of the ...

Page 15: ... with the retainer clip be sure the brush is properly nested in the motor frame before securing the screws 5 Repeat steps 2 thru 4 for the adjacent brush 6 Replace the metal band onto the mid section while carefully routing the wires through the grommet It is notched to fit in only one position Secure with single screw Reinstall cover over motor 11 5 VL 5 VLP 5 MOTOR BRUSH REPLACEMENT Remove metal...

Page 16: ...of the motor and pushing down until the spring clips on each brush snap into place 8 Reinstall metal cover over motor 11 6 MOTOR REPLACEMENT Disconnect all power from the loader system Disconnect the motor wiring from the junction box located on the lid of the chamber Remove the three springs that clamp the motor to the lid The motor can now be removed Check the gasket that seals the vacuum motor ...

Page 17: ... outlet B Stop Start Switch No voltage through switch Replace switch C Vacuum motor No voltage at motor See A B L D Filter Filter dirty Replace filter Also see G J E Air Ducts Obstructed Remove obstruction F Leaks in system Air leaking into system Replace gaskets repair leaks as necessary G Blowback air Increase pressure pressure incorrect Low pressure not to exceed 125 psi H Limit switch No volta...

Page 18: ...te the warranty A renewed warranty can be purchased directly from NOVATEC Please note that we always strive to satisfy our customers in whatever manner is deemed most expedient to overcome any issues in connection with our equipment Warranty Period Note All warranty periods commence with the shipment of the equipment to the customer VL VLP Series Loaders 2 Years Exclusions Routine maintenance repl...

Page 19: ... NOVATEC Inc 2013 All Rights Reserved VL VLP IM 4 12 2013 19 14 ELECTRICAL DRAWINGS VL VLP Series 115 V LOGO Control Wiring Diagram ...

Page 20: ... NOVATEC Inc 2013 All Rights Reserved VL VLP IM 4 12 2013 20 VL VLP Series 230 V LOGO Control Wiring Diagram ...

Page 21: ...ber gasket 05373 Filter Assembly 17 5 dia 400 mesh Nylon Optional Filter Assembly 17 5 dia Tight Weave 400 mesh Nylon filter with expanded metal backing clamped together with a rubber coated u channel perimeter seal 04545 Filter Assembly 17 5 dia Polyester Standard Filter Assembly 17 5 dia Polyester filter with expanded metal backing and molded rubber gasket 01695 Gasket seal 3 Standard Neoprene B...

Page 22: ...Polyester W PTFE For VLP 38 KIT S0016 Filter Kit includes three 3 of part 11644 Filter Cartridge Kit includes three 3 of part 11644 Filter Cartridge 4 OD X 2 5 ID X 10Lg Polyester W PTFE 1 Micron For VLP 12 19 01695 Gasket seal 3 Standard Neoprene Black 200 degree F Standard Neoprene 200 degree Gasket 3 Nominal Used for the Standard Discharge Gasket for the 2 dump valve 50026 Gasket seal 5 Standar...

Reviews: