20
Document: GFH-NT 1500-4000 IM 14 DEC 2016
Gas Fired Heater Instructions
©2016 NOVATEC, Inc. All Rights Reserved
9.0
I
f t
he burner controller detects an alarm, it turns the burner off and closes the “Alarm”
Interface Contact (3CR) to the NOVATOUCH PLC. The NOVATOUCH PLC Display on
the desiccant dryer will indicate the gas heater alarm
10.0
When the flame is on, and conditions a
re normal, the “Flame On” Interface Contact
(2CR) to the NOVATOUCH PLC on the desiccant dryer will be closed. The
NOVATOUCH PLC Display will indicate the flame is on.
The burner is controlled and monitored by the burner controller as shown on the electrical
schematic. The manufacture's bulletin for the burner controller is located elsewhere in this manual.
Burner Controller with manual
reset and indicator LED’s
Red Flame
On LED