Novar 738005000 Installation Instructions Manual Download Page 2

FCC Information

This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.

NOTE! This equipment has been tested and found to comply with the limits for

a Class B digital device pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference, in which case the user will be
required to correct the interference at his own expense.

CAUTION!

Any changes or modifications not expressly approved by Novar
Controls Corporation could void your authority to operate this
equipment.

Industry Canada

This digital apparatus does not exceed the Class B limits for radio noise emissions from
digital apparatus set out in the interference-causing equipment standard entitled

Digital

Apparatus

, ICES-003, of Industry Canada.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux
appareils numériques de Classe B préscrites dans la norme sur le matériel brouiller:

Appareils Numériques

, NMB-003, édictée par l’Industrie Canada.

Disclaimer

LOGIC ONE

® is a registered trademark of Novar Controls Corporation.

Lingo™ is a trademark of Novar Controls Corporation.

The material in this manual is for information purposes only. The contents and the
product it describes are subject to change without notice. Novar Controls Corporation
makes no representations or warranties with respect to this manual.

In no event shall Novar Controls Corporation be liable for technical or editorial omissions
or mistakes in this manual, nor shall it be liable for any damages, direct or incidental,
arising out of or related to the use of this manual.

Copyright © 2001 by Novar Controls Corporation. All rights reserved.

No part of this manual may be reproduced in any form or by any means

without prior written permission from Novar Controls Corporation.

Novar Controls Corporation

3333 Copley Road, Copley, OH 44321

Tel: (330) 670-1010

www.novarcontrols.com

Summary of Contents for 738005000

Page 1: ...INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION MAX ALLOWABLE AMBIENT TEMP 38 C 100 F 70 C 158 F REFER TO INSTALLATION I...

Page 2: ...tus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of Industry Canada Ce...

Page 3: ...neral fault input to receive contact closure signals from a variety of safety switches This input can be used to initiate an alarm or shut down the heat pump unit when the signal is received from the...

Page 4: ...e 1 3 Drill holes at the locations marked on the mounting surface 4 Insert metal screws not included through the module and the mounting surface and tighten to secure the module 2 DOC 569062000 2 20 0...

Page 5: ...ections The inputs are Terminals 1 through 10 located on the left side of the terminal strip see Figure 2 NOTE On the HPC Plus Terminals 13 and 14 under the Analog Outputs label are used as a digital...

Page 6: ...abel Each HPC or HPC Plus must use a Remote Temperature Sensor RTS UVC for discharge air and one of the following sensors UVC Wall Mount Indoor Temperature Sensor WTS UVC Futura Temperature Sensor FTS...

Page 7: ...have a status LED The software defines the length of time that the override remains in effect The Futura Temperature Sensor provides an override switch and status LED Refer to the installation instru...

Page 8: ...lus Only The HPC Plus damper analog output terminals are listed under the label Analog Outputs immediately to the right of the input connections Figure 2 Step Procedure 1 Connect the damper actuator s...

Page 9: ...regulated switched through Terminals 21 26 A F The relay outputs are isolated from the other connections to permit the additional power source The transformer powering the module can be used if it ha...

Page 10: ...the address of the HPC or HPC Plus being installed Refer to Figure 3 and set the switches with the correct address from 00 to 63 If a Lingo is used as the executive processor address switches 64 127 d...

Page 11: ...ed for proper operation by pressing it during a scheduled off mode The LED flashes rapidly until the override period ends The six relay output status LEDs indicate the status of each active digital ou...

Page 12: ...This page intentionally left blank 10 DOC 569062000 2 20 01 HPC HPC Plus Installation Instructions...

Reviews: