HS-1RS User Guide
Page 21
Trigger Time Out
This sets the maximum time how trigger procession continues during a scan attempt.
This command is not valid in Presentation Trigger Mode.
Use the command
TRGTIME x
(where ‘x’ is a value between 0 and 300.000 in 1ms steps)
, to set
the time between 1ms and 300 seconds. Default = 9900 (9.9 Seconds).
Note:
TRGTIME 0 = infinite trigger time out.
Setting examples:
Trigger Time Out 1.0 seconds
Trigger Time Out 5.0 seconds
* Trigger Time Out 9.9 seconds
Trigger Time Out 30.0 seconds
Good Read Delay
This sets the time period before the scanner can read another bar code.
Use the command
DLYGDRD x
(where ‘x’ is a value between 0 and 30.000 milliseconds)
, to set
the time between 0 (no delay) and 30.000 (=30 sec). Default time = 0 Seconds.
Note:
Good Read Delay is most effective when in Presentation Mode or when Multiple Symbol
Mode is turned on in combination with the other Trigger Modes.
Setting examples:
* No Good Read delay
Good Read delay 0.2 seconds
Good Read delay 0.5 seconds
Good Read delay 1.0 seconds