1.0 SPECIFICATIONS

Pressure 

500 to 1100 hPa standard range

Digital Accuracy* 

0.2 hPa (25°C) 

0.3 hPa (-40°C to +60°C)

Analog Accuracy**  0.05% of analog pressure range

Analog Temperature

Dependence** 

0.0017% of analog pressure 

range per °C (25°C reference)

Long Term Stability:  0.08% FS per year

*

  Defined as ±1 standard deviation from NIST-traceable 

pressure reference in clean, dry air.  Includes non-

linearity, hysteresis, repeatability, and calibration 

uncertainty.

**  Defined as ±1 standard deviation from ideal analog 

output.  Total analog output accuracy is the root sum 

square of digital accuracy, analog accuracy, and analog 

temperature dependence.

Output Rate 

1.8 Hz (max) to 1 per minute

Current Output 

4 to 20 mA or 0 to 20 mA 

12-bit resolution (1 in 4000)  

Selectable pressure range: 500 to 

1100 hPa (standard)

Serial Output 

Full-duplex RS-232 

Half-duplex RS-485 

SDI-12 

1200 to 38400 baud 

Continuous ASCII text 

Polled ASCII text 

NMEA 

0.01 hPa resolution

Supply Voltage 

7 to 30 VDC 

25 mA max (4-20 or 0-20 mA mode) 

1.5 mA max in SDI-12 mode 

8.5 mA (RS-232 or RS-485)

Case 

Fiber-reinforced thermoplastic

Weight 

44 g (1.5 oz)

INSTRUCTIONS

MODEL 61402L

BAROMETRIC PRESSURE SENSOR