Novalynx 230-600C Quick Start Manual Download Page 1

 

Barometric Pressure

 

NovaLynx Corporation 

PO Box 240 Grass Valley CA 95945 

DOC 230-600C IS 20210526

 

+1 (530) 823-7185 [email protected] 

www.novalynx.com 

230-600C Barometric Pressure Sensor 

 
 

The 

230-600C Barometric Pressure Sensor

 offers unparalleled 

performance and flexibility for atmospheric pressure measurement. It 
combines high accuracy and low power over a wide range of pressures 
and temperatures. 
 
The standard output is 4-20 mA over the full range of 500-1100 hPa. The 
span can be programmed anywhere within the full operating range. Other 
programmable options include 0-20 mA output, RS232, RS485 or SDI-12. 
 
The screw terminal block is de-pluggable. Cable sold separately. 

 

 

A

 OUTPUT (TX)

+

 PWR (7-30 VDC)

-

 PWR

4-20 mA SIGNAL

B

 OUTPUT (RX)

EARTH GROUND

 

GREEN

RED

BLACK

WHITE

BROWN

SHIELD

R

X

-B

I-

O

U

T

R

E

F

P

W

R

T

X

-A

 / 

S

D

I

P

re

ss

ur

P

or

t

- - - - -

DWG 820-0006-01

230-600C

BAROMETRIC PRESSURE

DEFAULT OUTPUT

RANGE: 500-1100 hPa

SIGNAL: 4 to 20 mA

Consult RM Young 

Model 61402L

 instruction manual

for jumper settings to enable other options

INSULATE UNUSED WIRES

Recommended Cable

 

PN 330-0524 

5C 24AWG, Shielded

 

 

 
Ordering Information 

 

230-600C 

Barometric Pressure Sensor, 4-20 mA output 

330-0524 

Cable 5C 24AWG Shielded, per foot 

 

Reviews: