NovaLynx Corporation_____________________________________________________________________________ 

 

 

200-WS-23 

Page 2 

Oct 2020 

 

Receiving and Unpacking

 

 

Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation 
immediately concerning any discrepancy. Inspect equipment to detect any damage that may have 
occurred during shipment. In the event of damage, any claim for loss must be filed immediately with 
the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee 
to contact NovaLynx Corporation for instructions. 

 

Returns

 

 

If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 
p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned 
equipment a description of the problem and the name, address, and daytime phone number of the 
sender. Carefully pack the equipment to prevent damage or additional damage during the return 
shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing 
facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service 
and obtain assistance with the packaging. Please write the RA# on the outside of the box. 

 

Warranty

 

 

NovaLynx Corporation warrants that its products are free from defects in material and workmanship 
under normal use and service for a period of one year from the date of shipment from the factory. 
NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) 
replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx 
Corporation's liability exceed product's original purchase price. This warranty does not apply to any 
equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been 
subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of 
all warranties of fitness and in lieu of the warranty of merchantability. 

 

Address

 

 

NovaLynx Corporation 
431 Crown Point Circle, Suite 120 
Grass Valley, CA 95945-9531 USA 
Phone: (530) 823-7185 
Email: [email protected] 
Website: www.novalynx.com

 

 

Copyright © 1988-2020 by NovaLynx Corporation 

 

 

Summary of Contents for 200-WS-23

Page 1: ...DOC 200 WS 23 UM 20201012 200 WS 23 User Manual Current Loop Wind Sensor 200 WS 23 Wind Speed Direction 200 WS 23S Wind Speed Only Phone 530 823 7185 Email nova novalynx com Website www novalynx com...

Page 2: ...in the case of delicate or sensitive items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with the packaging P...

Page 3: ...CONTENTS 1 FORWARD 4 2 INTRODUCTION 4 3 SPECIFICATIONS 5 4 INSTALLATION 5 5 CONNECTIONS 6 6 CALIBRATION 7 APPENDIX A Wind Speed and Direction Wire Diagram 8 APPENDIX B Wind Speed Only Wire Diagram 9 2...

Page 4: ...power supply is not needed The driver circuitry is protected in a NEMA enclosure suitable for indoor or outdoor mounting The anemometer is a 200 WS 01B Wind Speed sensor that includes 40 of cable and...

Page 5: ...200 WS 23S KM 4 20 mA 0 200 kph Loop supply voltage range Connection Operating temperature range NEMA enclosure dimensions Cable to user equipment Measurement range Speed Constant Transducer type Spe...

Page 6: ...Tighten the gland nut 3 Make sure there is a drip loop below the transmitter enclosure so that any moisture on the cable will not seep into the enclosure This is particularly important since the seal...

Page 7: ...n of the monitoring equipment Disconnect the 200 WS 23 or 200 WS 23S from the device before doing these tests 1 Use a 4 20 mA signal generator to feed 6 mA into the selected channel on your monitoring...

Page 8: ...2 3 4 GND WS REF REF EXC WD IMPORTANT CONNECT EARTH GROUND 200 WS 02F GREEN RED BLACK WHITE SHIELD BROWN 8 30 Vdc Wind Direction Signal 8 30 Vdc Wind Speed Signal 4 20 mA Input 8 30 Vdc 1 Signal Out...

Page 9: ...ogger Power WIRING DIAGRAM 200 WS 23S JDC 9 03 2020 860 0029 01 1 2 3 4 GND WS REF REF EXC WD IMPORTANT CONNECT EARTH GROUND 200 WS 01B RED SHIELD BLACK 8 30 Vdc Wind Speed Signal 4 20 mA Input 8 30 V...

Reviews: